Suppr超能文献

使用带光滑栓钉的锁定钢板对肱骨近端骨折进行切开复位内固定的评估——一项回顾性研究。

Evaluation of open reduction and internal fixation of proximal humerus fractures using a locking plate with smooth pegs - A retrospective study.

作者信息

Hansson Frida, Riddar Magdalena, Ekelund Anders

机构信息

Department of Orthopaedics, Capio St Görans Hospital, Stockholm, Sweden.

出版信息

Shoulder Elbow. 2019 Dec;11(6):411-418. doi: 10.1177/1758573218791166. Epub 2018 Aug 7.

Abstract

BACKGROUND

Optimal treatment of displaced proximal humeral fractures is controversial. This retrospective study aims to identify complications and clinical outcomes using a locking plate with smooth pegs instead of screws (S3 plate).

METHOD

Eighty-two patients with displaced proximal humeral fracture classified with 2-4 fragments (Neer's classification) treated with open reduction and internal fixation (ORIF) with S3 plate were studied retrospectively. Clinical outcome according to constant score; Single Shoulder Value; Disabilities of Arm, Shoulder and Hand; and European Quality of life-5 dimensions and complication rate defined radiologically including peg penetration, avascular necrosis, and loss of reduction was assessed minimum 2.5 years after surgery.

RESULTS

A total of 11 peg penetrations were identified (13.6%). Avascular necrosis was seen in 8.5% (n = 7). Mean constant score at follow-up was 64.4 with a relative constant score of 87% (standard deviation 18%) compared to the contralateral uninjured side. The mean Disabilities of Arm, Shoulder and Hand score was 12.7 and mean European Quality of life-5 dimensions score 0.83. The mean Single Shoulder Value was 78.3. No cases of deep infection were seen.

CONCLUSIONS

Fixation with S3 plate shows a proper osteosynthesis and the functional outcome is good. Symptomatic peg penetrations are rare and the incidence is lower compared to what has been reported with locked screws.

摘要

背景

移位型肱骨近端骨折的最佳治疗方法存在争议。本回顾性研究旨在确定使用带光滑栓钉而非螺钉的锁定钢板(S3钢板)的并发症和临床结果。

方法

回顾性研究82例采用S3钢板切开复位内固定(ORIF)治疗的2-4块骨折的移位型肱骨近端骨折患者(Neer分类)。根据Constant评分、单肩值、手臂、肩部和手部功能障碍以及欧洲生活质量5维度评估临床结果,并在术后至少2.5年评估放射学定义的并发症发生率,包括栓钉穿透、缺血性坏死和复位丢失。

结果

共发现11例栓钉穿透(13.6%)。缺血性坏死发生率为8.5%(n = 7)。随访时的平均Constant评分为64.4,与对侧未受伤侧相比,相对Constant评分为87%(标准差18%)。手臂、肩部和手部功能障碍的平均评分为12.7,欧洲生活质量5维度的平均评分为0.83。单肩值平均为78.3。未发现深部感染病例。

结论

使用S3钢板固定显示出良好的骨愈合,功能结果良好。有症状的栓钉穿透很少见,与锁定螺钉的报道相比发生率更低。

相似文献

本文引用的文献

2
Epidemiology of proximal humerus fractures.肱骨近端骨折的流行病学
Arch Osteoporos. 2015;10:209. doi: 10.1007/s11657-015-0209-4. Epub 2015 Feb 13.
6
Predicting failure after surgical fixation of proximal humerus fractures.预测肱骨近端骨折手术后的失败。
Injury. 2011 Nov;42(11):1283-8. doi: 10.1016/j.injury.2011.01.017. Epub 2011 Feb 9.