Hansson Frida, Riddar Magdalena, Ekelund Anders
Department of Orthopaedics, Capio St Görans Hospital, Stockholm, Sweden.
Shoulder Elbow. 2019 Dec;11(6):411-418. doi: 10.1177/1758573218791166. Epub 2018 Aug 7.
Optimal treatment of displaced proximal humeral fractures is controversial. This retrospective study aims to identify complications and clinical outcomes using a locking plate with smooth pegs instead of screws (S3 plate).
Eighty-two patients with displaced proximal humeral fracture classified with 2-4 fragments (Neer's classification) treated with open reduction and internal fixation (ORIF) with S3 plate were studied retrospectively. Clinical outcome according to constant score; Single Shoulder Value; Disabilities of Arm, Shoulder and Hand; and European Quality of life-5 dimensions and complication rate defined radiologically including peg penetration, avascular necrosis, and loss of reduction was assessed minimum 2.5 years after surgery.
A total of 11 peg penetrations were identified (13.6%). Avascular necrosis was seen in 8.5% (n = 7). Mean constant score at follow-up was 64.4 with a relative constant score of 87% (standard deviation 18%) compared to the contralateral uninjured side. The mean Disabilities of Arm, Shoulder and Hand score was 12.7 and mean European Quality of life-5 dimensions score 0.83. The mean Single Shoulder Value was 78.3. No cases of deep infection were seen.
Fixation with S3 plate shows a proper osteosynthesis and the functional outcome is good. Symptomatic peg penetrations are rare and the incidence is lower compared to what has been reported with locked screws.
移位型肱骨近端骨折的最佳治疗方法存在争议。本回顾性研究旨在确定使用带光滑栓钉而非螺钉的锁定钢板(S3钢板)的并发症和临床结果。
回顾性研究82例采用S3钢板切开复位内固定(ORIF)治疗的2-4块骨折的移位型肱骨近端骨折患者(Neer分类)。根据Constant评分、单肩值、手臂、肩部和手部功能障碍以及欧洲生活质量5维度评估临床结果,并在术后至少2.5年评估放射学定义的并发症发生率,包括栓钉穿透、缺血性坏死和复位丢失。
共发现11例栓钉穿透(13.6%)。缺血性坏死发生率为8.5%(n = 7)。随访时的平均Constant评分为64.4,与对侧未受伤侧相比,相对Constant评分为87%(标准差18%)。手臂、肩部和手部功能障碍的平均评分为12.7,欧洲生活质量5维度的平均评分为0.83。单肩值平均为78.3。未发现深部感染病例。
使用S3钢板固定显示出良好的骨愈合,功能结果良好。有症状的栓钉穿透很少见,与锁定螺钉的报道相比发生率更低。