Suppr超能文献

万古霉素浸泡半腱肌移植物不会改变其生物力学性能:一项使用活体供者移植物的生物力学体外对照研究。

Presoaking of Semitendinosus Graft With Vancomycin Does Not Alter Its Biomechanical Properties: A Biomechanical In Vitro-Controlled Study Using Graft From Living Donors.

机构信息

Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France.

Institute of Movement and Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France; Institut de Chirurgie Orthopédique et Sportive, Marseille, France.

出版信息

Arthroscopy. 2020 Aug;36(8):2231-2236. doi: 10.1016/j.arthro.2020.03.037. Epub 2020 Apr 15.

Abstract

PURPOSE

To compare the biomechanical properties of human semitendinosus graft presoaked with or without vancomycin under a load to failure tensile test.

METHODS

Thirty semitendinosus grafts harvested during anterior cruciate ligament reconstruction were included. These were dissected equally into 2 halves and subsequently randomly allocated to a vancomycin group and to a control group. A digital caliper was used to precisely measure each samples thickness, length, and width. For the vancomycin group, samples were presoaked in a solution of 5 mg/mL vancomycin for a duration of 10 minutes and the control group samples were presoaked in a physiological serum equally for 10 minutes. Mechanical testing was performed on a universal testing machine (Instron 5566-A) after a preconditioning of 10 cycles of 1 mm extension and a progression of 10 mm/min to failure for each sample. The stress-strain curve was obtained to determine the elastic modulus (Young's modulus), the ultimate tensile stress, the ultimate tensile elongation (UTE) before failure and the elasticity limit.

RESULTS

For the control group, the average Young's modulus value was 4.8 ± 0.8, the average UTS was 25.2 ± 5.2 MPa, the average percentage of UTE was 78 ± 17%, and the average elasticity limit value was 17.3 ± 5.3 MPa. For the vancomycin group, the average Young's modulus value was 4.7 ± 0.9, the average ultimate tensile stress was 24.1 ± 6.1 MPa, the average percentage of UTE was 82 ± 14%, and the average elasticity limit value was 18.5 ± 5.9 MPa. No significant difference was observed between the 2 groups for all investigated parameters.

CONCLUSIONS

Presoaking of human semitendinosus graft with vancomycin does not alter its biomechanical properties.

CLINICAL RELEVANCE

This study demonstrates that vancomycin presoaking used to prevent post-anterior cruciate ligament reconstruction septic arthritis does not affect immediate biomechanical properties of semitendinosus tendons.

摘要

目的

比较负载至失效拉伸试验中预先浸泡万古霉素与不浸泡万古霉素的人半腱肌腱移植物的生物力学性能。

方法

纳入 30 例前交叉韧带重建术中采集的半腱肌腱移植物。这些移植物被均等剖分为 2 半,然后随机分配到万古霉素组和对照组。使用数字卡尺精确测量每个样本的厚度、长度和宽度。万古霉素组的样本在 5mg/ml 万古霉素溶液中浸泡 10 分钟,对照组的样本在生理盐水中浸泡 10 分钟。对每个样本进行 10 个 1mm 延伸的预条件循环和 10mm/min 的进展至失效的机械测试,在万能试验机(Instron 5566-A)上进行。获得应力-应变曲线以确定弹性模量(杨氏模量)、极限拉伸强度、失效前的极限拉伸伸长率(UTE)和弹性极限。

结果

对于对照组,平均杨氏模量值为 4.8±0.8MPa,平均 UTS 为 25.2±5.2MPa,平均 UTE 百分比为 78±17%,平均弹性极限值为 17.3±5.3MPa。万古霉素组的平均杨氏模量值为 4.7±0.9MPa,平均 UTS 为 24.1±6.1MPa,平均 UTE 百分比为 82±14%,平均弹性极限值为 18.5±5.9MPa。两组在所有研究参数方面均无显著差异。

结论

万古霉素预先浸泡人半腱肌腱移植物不会改变其生物力学特性。

临床相关性

本研究表明,用于预防前交叉韧带重建术后化脓性关节炎的万古霉素预先浸泡不会影响半腱肌腱的即时生物力学特性。