Suppr超能文献

评估在优势眼植入具有中度附加屈光度的变迹衍射多焦点环曲面人工晶状体、在对侧眼植入具有更高附加屈光度的该人工晶状体后的屈光和视觉效果。

Evaluating Refractive and Visual Outcomes After Bilateral Implantation of an Apodized Diffractive Multifocal Toric Intraocular Lens with a Moderate Add in the Dominant Eye and a Higher Add in the Fellow Eye.

作者信息

Blehm Clayton, Potvin Richard

机构信息

Gainesville Eye Associates, Gainesville, GA, USA.

Science in Vision, Akron, NY, USA.

出版信息

Clin Ophthalmol. 2020 Apr 9;14:1035-1041. doi: 10.2147/OPTH.S246271. eCollection 2020.

Abstract

PURPOSE

To review refractive, visual acuity, defocus curve and subjective visual quality results after bilateral implantation of an apodized diffractive toric intraocular lens (IOL) with a moderate add in the dominant eye and a higher add in the non-dominant eye.

SETTING

One site in Gainesville, GA, USA.

DESIGN

Single arm, non-randomized prospective study.

METHODS

This was a single-arm prospective study of visual acuity and subjective visual quality after implantation of a toric low-add apodized diffractive multifocal IOL in the dominant eye and a higher add IOL of the same type in the non-dominant eye three months after surgery. Binocular visual acuity at 4 m, 60 cm and 40 cm was tested. Other tests included refraction, defocus curve measurement and evaluation of the quality of vision. Toric IOL orientation was also measured.

RESULTS

A total of 29 subjects were enrolled. There were no statistically significant differences in the mean keratometry, corneal astigmatism or IOL sphere power implanted in the dominant and non-dominant eyes. Vision was preferred without any correction in more than half of the eyes tested (32/58, 55%). The residual refractive astigmatism was ≤ 0.50 D in 100% of eyes. Seventy-five percent of subjects (22/29) had 0.10 logMAR (20/25 Snellen) binocular uncorrected visual acuity at all tested distances. Glare and haloes were the most common visual disturbances, but most subjects (22/29, 76%) reported that they were not bothered by any visual disturbances. In 97% of eyes (56/58), the measured difference in orientation between 1 month and 3 months was less than 5 degrees, with no change more than 14 degrees.

CONCLUSION

This blended bifocal IOL modality appears to be well-tolerated by subjects with a good range of vision and minimal bother from visual disturbances.

摘要

目的

回顾在优势眼植入具有适度附加度数的变迹衍射复曲面人工晶状体(IOL),非优势眼植入更高附加度数的该类人工晶状体后,双眼的屈光、视力、散焦曲线及主观视觉质量结果。

设置

美国佐治亚州盖恩斯维尔的一个地点。

设计

单臂、非随机前瞻性研究。

方法

这是一项单臂前瞻性研究,在手术后三个月,于优势眼植入复曲面低附加度数变迹衍射多焦点IOL,非优势眼植入同类型更高附加度数的IOL,之后测试双眼在4米、60厘米和40厘米处的视力。其他测试包括验光、散焦曲线测量和视觉质量评估。还测量了复曲面IOL的轴向。

结果

共纳入29名受试者。优势眼和非优势眼植入的平均角膜曲率、角膜散光或IOL球镜度数无统计学显著差异。超过一半接受测试的眼睛(32/58,55%)在未矫正状态下视力更佳。100%的眼睛残余屈光性散光≤0.50 D。75%的受试者(22/29)在所有测试距离下双眼未矫正视力为0.10 logMAR(20/25 Snellen)。眩光和光晕是最常见的视觉干扰,但大多数受试者(22/29,76%)报告称未受任何视觉干扰困扰。在97%的眼睛(�6/58)中,1个月和3个月时测量的轴向差异小于5度,变化超过14度的情况未出现。

结论

这种混合双焦点IOL模式似乎能被视力范围良好且视觉干扰困扰极小的受试者很好地耐受。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a9d6/7154035/e9cbb6bd29e4/OPTH-14-1035-g0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验