Suppr超能文献

一种用于测定补体介导的脂质体免疫裂解的简单荧光方法。

A simple fluorescent method to determine complement-mediated liposome immune lysis.

作者信息

Smolarsky M, Teitelbaum D, Sela M, Gitler C

出版信息

J Immunol Methods. 1977;15(3):255-65. doi: 10.1016/0022-1759(77)90063-1.

Abstract

A simple inexpective method is described to study the kinetics of complement-mediated immune lysis of liposomes containing sheep red blood cell lipid antigens. It is based on the fact that trapping the fluorescent molecule 1-aminonaphthalene-3,6,8-trisulfonate and the dynamic quencher, alpha, alpha'-dipyridinium p-xylene dibromide within the liposome inner volume results in an extinguished fluorescence signal. On addition of helmolysin plus active complement, liposome lysis occurs. The exit of the fluorophore and quencher and their subsequent dilution in the external volume abolishes the quenching, resulting in a high fluorescence signal. The details of the method are described as well as the initial kinetic results.

摘要

描述了一种简单的非选择性方法来研究含有绵羊红细胞脂质抗原的脂质体补体介导免疫裂解的动力学。该方法基于这样一个事实:将荧光分子1-氨基萘-3,6,8-三磺酸盐和动态猝灭剂α,α'-二吡啶鎓对二甲苯二溴化物捕获在脂质体内腔中会导致荧光信号熄灭。加入溶血素和活性补体后,脂质体发生裂解。荧光团和猝灭剂的释放以及它们随后在外部体积中的稀释消除了猝灭作用,从而产生高荧光信号。文中描述了该方法的详细信息以及初步的动力学结果。