Abstract

The separation of free from bound antigen is not required in homogeneous enzyme immunoassays (EMIT). Therefore this technique can easily be mechanized. For the mechanization of the enzyme immunological determination of serum levels of Phenytoine the fast analyzer (CENTRIFICHEM) was found most satisfactory in our laboratory. The marked advantages over manual methods are: 1. The amount of sample and reagents needed can be reduced by half. 2. The intra- and interassay variance are significantly better compared to values found with manual techniques. 3. 60 samples can be determined in duplicate in under two hours.

摘要

在均相酶免疫分析(EMIT)中,无需将游离抗原与结合抗原分离。因此,该技术很容易实现机械化。在我们实验室中,发现快速分析仪(CENTRIFICHEM)最适合用于苯妥英血清水平的酶免疫测定的机械化操作。与手工方法相比,其显著优势在于:1. 所需样本和试剂的量可减少一半。2. 与手工技术相比,批内和批间差异明显更小。3. 可在两小时内对60个样本进行双份测定。