Suppr超能文献

两种三焦点人工晶状体的视觉和屈光效果比较。

Comparison of visual and refractive outcomes of 2 trifocal intraocular lenses.

机构信息

From the Department of Ophthalmology, Hospital da Luz, Lisbon, Portugal.

出版信息

J Cataract Refract Surg. 2020 May;46(5):694-699. doi: 10.1097/j.jcrs.0000000000000118.

Abstract

PURPOSE

To compare clinical outcomes after cataract surgery and bilateral implantation of 2 diffractive trifocal toric intraocular lenses (IOLs).

SETTING

Hospital da Luz, Lisbon, Portugal.

DESIGN

Double-arm, randomized, prospective case series.

METHODS

A total of 60 patients were randomly allocated to receive bilateral implantation of either the FineVision Pod FT toric IOL (PhysIOL) or the AcrySof IQ PanOptix toric IOL (Alcon). Visual and refractive outcomes, contrast sensitivity, IOL misalignment, and quality of vision outcomes (QoV questionnaire) were evaluated at 3 months postoperatively. Surgically induced astigmatic changes were evaluated by vector analysis.

RESULTS

Each group (FineVision toric and AcrySof IQ PanOptix toric) comprised 30 patients (60 eyes). No significant differences between groups were found regarding uncorrected and corrected distance and near visual outcomes (P ≥ .333). Mean postoperative distance-corrected intermediate visual acuity at 60 cm was 0.04 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and 0.09 ± 0.11 logMAR in the PanOptix and Pod FT group, respectively (P = .032). Mean IOL axis misalignment was 1.59 degrees ± 2.15 degrees (PanOptix group) and 1.89 degrees ± 3.31 degrees (Pod FT group) (P = .821). Mean magnitude of error of astigmatic correction was -0.09 diopters (D) and -0.11 D in the PanOptix group and Pod FT group, respectively (P = .333). Contrast sensitivity, QoV scores for the presence of photic phenomena, and the level of spectacle independence were similar in both groups (P > .05).

CONCLUSIONS

Both trifocal toric IOLs allowed complete patient visual restoration, and good spectacle independence and good visual quality outcomes. The PanOptix IOL provided superior intermediate visual acuity for distances around 60 cm.

摘要

目的

比较白内障术后双侧植入 2 种衍射性三焦点散光人工晶状体(IOL)的临床效果。

设置

葡萄牙里斯本 Luz 医院。

设计

双臂、随机、前瞻性病例系列。

方法

共 60 例患者被随机分配接受 FineVision Pod FT 散光 IOL(PhysIOL)或 AcrySof IQ PanOptix 散光 IOL(Alcon)的双侧植入。术后 3 个月评估视力和屈光结果、对比敏感度、IOL 偏心度和视觉质量结果(QoV 问卷)。通过向量分析评估手术引起的散光变化。

结果

每组(FineVision 散光和 AcrySof IQ PanOptix 散光)各 30 例(60 眼)。两组在未矫正和矫正的远、近视力结果方面无显著差异(P≥.333)。60cm 处术后距离校正中间视力的平均结果分别为 0.04±0.09 最小角分辨率对数视力(logMAR)和 0.09±0.11 logMAR,在 PanOptix 和 Pod FT 组中(P=0.032)。平均 IOL 轴偏心度为 1.59°±2.15°(PanOptix 组)和 1.89°±3.31°(Pod FT 组)(P=0.821)。平均散光矫正误差幅度分别为-0.09 屈光度(D)和-0.11 D,在 PanOptix 组和 Pod FT 组中(P=0.333)。两组间对比敏感度、存在光幻现象的 QoV 评分和眼镜独立水平相似(P>0.05)。

结论

两种三焦点散光 IOL 均能完全恢复患者视力,具有良好的眼镜独立和良好的视觉质量效果。PanOptix IOL 为 60cm 左右的距离提供了更好的中间视力。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验