Pastor-Pascual Francisco, Orts-Vila Paz, Tañá-Sanz Pedro, Tañá-Sanz Santiago, Tañá-Rivero Pedro
Cataract and Refractive Surgery Department, Oftalvist Valencia, Valencia, Spain.
Cataract and Refractive Surgery Department, Oftalvist Alicante, Alicante, Spain.
Clin Ophthalmol. 2024 Jul 11;18:2009-2020. doi: 10.2147/OPTH.S466091. eCollection 2024.
To assess the refractive and visual outcomes at different distances following cataract surgery with implantation of an omnidirectional aberration-free diffractive trifocal toric intraocular lens (IOL).
A total of 24 patients who underwent bilateral implantation with the TrivaT-aAY IOL were analyzed at 3-4 months post-surgery. Refractive error, monocular and binocular uncorrected and corrected-distance visual acuity (UDVA, CDVA), uncorrected and corrected-distance intermediate visual acuity (UIVA, CDIVA) at 60 cm, uncorrected and corrected-distance near visual acuity (UNVA, CDNVA) at 40 cm, monocular and binocular defocus curve and rotational stability were measured. Patients also completed the Catquest-9SF questionnaire at the last postoperative visit.
The postoperative mean values of binocular logMAR CDVA, CDIVA and CDNVA were -0.06±0.06, 0.05±0.07 and 0.07±0.08, respectively. One hundred percent of patients showed a cumulative binocular CDVA ≥20/25, and 95.83% of patients showed a cumulative binocular CDIVA and CDNVA ≥20/32. The mean postoperative spherical equivalent was 0.07±0.26D and 100% and 97.92% eyes were within ±1.00D and ±0.50D, respectively. The mean postoperative refractive cylinder was -0.22±0.29D and 100% and 89.58% eyes showed a value ≤1.00D and ≤0.50D, respectively. The defocus curves showed a wide range of useful vision, with visual acuity values >0.2 logMAR. Mean absolute IOL rotation was 2.19±2.17 degrees and all eyes had a rotation <10 degrees. For the questionnaire, 95.83% of patients reported being quite satisfied to very satisfied with their vision and about 79.17% did not report any difficulty with their vision in their everyday life. Between 83.33% and 95.83% of patients reported no difficulty performing different tasks. No intra- and postoperative complications were reported during the follow-up.
Our study shows that the TrivaT-aAY IOL provides good visual acuities at all distances and refractive outcomes with excellent rotational stability and with high satisfaction among our patients after its implantation.
评估植入全向无像差衍射三焦点环曲面人工晶状体(IOL)后不同距离的屈光和视觉效果。
对24例行双侧TrivaT-aAY IOL植入术的患者在术后3 - 4个月进行分析。测量屈光不正、单眼和双眼未矫正及矫正远视力(UDVA、CDVA)、60 cm处未矫正及矫正中视力(UIVA、CDIVA)、40 cm处未矫正及矫正近视力(UNVA、CDNVA)、单眼和双眼散焦曲线以及旋转稳定性。患者在术后最后一次随访时还完成了Catquest-9SF问卷。
双眼logMAR CDVA、CDIVA和CDNVA的术后平均值分别为-0.06±0.06、0.05±0.07和0.07±0.08。100%的患者双眼累积CDVA≥20/25,95.83%的患者双眼累积CDIVA和CDNVA≥20/32。术后平均球镜等效度为0.07±0.26D,100%和97.92%的眼分别在±1.00D和±0.50D范围内。术后平均屈光柱镜为-0.22±0.29D,100%和89.58%的眼分别显示值≤1.00D和≤0.50D。散焦曲线显示了广泛的有用视力范围,视力值>0.2 logMAR。IOL平均绝对旋转度为2.19±2.17度,所有眼的旋转度<10度。对于问卷,95.83%的患者报告对其视力非常满意,约79.17%的患者在日常生活中未报告任何视力困难。83.33%至95.83%的患者报告在执行不同任务时没有困难。随访期间未报告任何术中及术后并发症。
我们的研究表明,TrivaT-aAY IOL在所有距离均提供良好的视力和屈光效果,具有出色的旋转稳定性,植入后患者满意度高。