Clinical Performance of an Omnidirectional Aberration-Free Trifocal Toric Intraocular Lens.

作者信息

Pastor-Pascual Francisco, Orts-Vila Paz, Tañá-Sanz Pedro, Tañá-Sanz Santiago, Tañá-Rivero Pedro

机构信息

Cataract and Refractive Surgery Department, Oftalvist Valencia, Valencia, Spain.

Cataract and Refractive Surgery Department, Oftalvist Alicante, Alicante, Spain.

出版信息

Clin Ophthalmol. 2024 Jul 11;18:2009-2020. doi: 10.2147/OPTH.S466091. eCollection 2024.

Abstract

PURPOSE

To assess the refractive and visual outcomes at different distances following cataract surgery with implantation of an omnidirectional aberration-free diffractive trifocal toric intraocular lens (IOL).

METHODS

A total of 24 patients who underwent bilateral implantation with the TrivaT-aAY IOL were analyzed at 3-4 months post-surgery. Refractive error, monocular and binocular uncorrected and corrected-distance visual acuity (UDVA, CDVA), uncorrected and corrected-distance intermediate visual acuity (UIVA, CDIVA) at 60 cm, uncorrected and corrected-distance near visual acuity (UNVA, CDNVA) at 40 cm, monocular and binocular defocus curve and rotational stability were measured. Patients also completed the Catquest-9SF questionnaire at the last postoperative visit.

RESULTS

The postoperative mean values of binocular logMAR CDVA, CDIVA and CDNVA were -0.06±0.06, 0.05±0.07 and 0.07±0.08, respectively. One hundred percent of patients showed a cumulative binocular CDVA ≥20/25, and 95.83% of patients showed a cumulative binocular CDIVA and CDNVA ≥20/32. The mean postoperative spherical equivalent was 0.07±0.26D and 100% and 97.92% eyes were within ±1.00D and ±0.50D, respectively. The mean postoperative refractive cylinder was -0.22±0.29D and 100% and 89.58% eyes showed a value ≤1.00D and ≤0.50D, respectively. The defocus curves showed a wide range of useful vision, with visual acuity values >0.2 logMAR. Mean absolute IOL rotation was 2.19±2.17 degrees and all eyes had a rotation <10 degrees. For the questionnaire, 95.83% of patients reported being quite satisfied to very satisfied with their vision and about 79.17% did not report any difficulty with their vision in their everyday life. Between 83.33% and 95.83% of patients reported no difficulty performing different tasks. No intra- and postoperative complications were reported during the follow-up.

CONCLUSION

Our study shows that the TrivaT-aAY IOL provides good visual acuities at all distances and refractive outcomes with excellent rotational stability and with high satisfaction among our patients after its implantation.

摘要

目的

评估植入全向无像差衍射三焦点环曲面人工晶状体(IOL)后不同距离的屈光和视觉效果。

方法

对24例行双侧TrivaT-aAY IOL植入术的患者在术后3 - 4个月进行分析。测量屈光不正、单眼和双眼未矫正及矫正远视力(UDVA、CDVA)、60 cm处未矫正及矫正中视力(UIVA、CDIVA)、40 cm处未矫正及矫正近视力(UNVA、CDNVA)、单眼和双眼散焦曲线以及旋转稳定性。患者在术后最后一次随访时还完成了Catquest-9SF问卷。

结果

双眼logMAR CDVA、CDIVA和CDNVA的术后平均值分别为-0.06±0.06、0.05±0.07和0.07±0.08。100%的患者双眼累积CDVA≥20/25,95.83%的患者双眼累积CDIVA和CDNVA≥20/32。术后平均球镜等效度为0.07±0.26D,100%和97.92%的眼分别在±1.00D和±0.50D范围内。术后平均屈光柱镜为-0.22±0.29D,100%和89.58%的眼分别显示值≤1.00D和≤0.50D。散焦曲线显示了广泛的有用视力范围,视力值>0.2 logMAR。IOL平均绝对旋转度为2.19±2.17度,所有眼的旋转度<10度。对于问卷,95.83%的患者报告对其视力非常满意,约79.17%的患者在日常生活中未报告任何视力困难。83.33%至95.83%的患者报告在执行不同任务时没有困难。随访期间未报告任何术中及术后并发症。

结论

我们的研究表明,TrivaT-aAY IOL在所有距离均提供良好的视力和屈光效果,具有出色的旋转稳定性,植入后患者满意度高。