Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with Rubidium PET imaging.

作者信息

Acampa Wanda, Zampella Emilia, Assante Roberta, Genova Andrea, De Simini Giovanni, Mannarino Teresa, D'Antonio Adriana, Gaudieri Valeria, Nappi Carmela, Buongiorno Pietro, Mainolfi Ciro Gabriele, Petretta Mario, Cuocolo Alberto

机构信息

Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.

Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy.

出版信息

J Nucl Cardiol. 2021 Dec;28(6):2827-2839. doi: 10.1007/s12350-020-02129-w. Epub 2020 May 7.

Abstract

BACKGROUND

We measured myocardial blood flow (MBF) and perfusion reserve (MPR) by dynamic CZT-SPECT and Rb-PET in patients with suspected or known coronary artery disease (CAD) and compared the accuracy of the two methods in predicting obstructive CAD.

METHODS

Twenty-five patients with available coronary angiography data underwent Tc-sestamibi CZT-SPECT and Rb-PET cardiac imaging. Stress and rest MBF and MPR were calculated by both methods and compared. Diagnostic accuracies of CZT-SPECT and PET were also assessed using a receiver-operator-characteristic curve.

RESULTS

CZT-SPECT yielded similar baseline MBF, but higher hyperemic MBF and MPR values compared to PET. There was a modest correlation between the two methods for MPR (r = 0.56, P < .01). MPR by CZT-SPECT showed a good ability in identify a reduced MPR by PET, with an area under the curve of 0.85. A MPR cut-off of 2.5 was identified by CZT-SPECT for detection of abnormal MPR by PET, with a sensitivity, specificity and accuracy of 86%, 73% and 80%. The area under the curve for the identification of obstructive CAD by regional MPR were 0.83 for CZT-SPECT and 0.84 for PET (P = .90). At CZT-SPECT, a regional MPR of 2.1 provided the best trade-off between sensitivity and specificity for identifying obstructive CAD. Diagnostic accuracy of CZT-SPECT and PET using respective cut-off values was comparable (P = .62).

CONCLUSION

Hyperemic MBF and MPR values obtained by CZT-SPECT are higher than those measured by Rb-PET imaging, with a moderate correlation between the two methods. CZT-SPECT shows good diagnostic accuracy for the identification of obstructive CAD. These findings may encourage the use of this new technique to a better risk stratification and patient management.

摘要

背景

我们通过动态CZT单光子发射计算机断层扫描(SPECT)和铷(Rb)-正电子发射断层扫描(PET)测量了疑似或已知冠状动脉疾病(CAD)患者的心肌血流量(MBF)和灌注储备(MPR),并比较了这两种方法在预测阻塞性CAD方面的准确性。

方法

25例有冠状动脉造影数据的患者接受了锝-司他比CZT-SPECT和Rb-PET心脏成像。两种方法均计算了负荷和静息状态下的MBF和MPR并进行比较。还使用受试者工作特征曲线评估了CZT-SPECT和PET的诊断准确性。

结果

与PET相比,CZT-SPECT得出的基线MBF相似,但充血MBF和MPR值更高。两种方法在MPR方面存在适度相关性(r = 0.56,P <.01)。CZT-SPECT得出的MPR显示出很好的识别PET测量的降低的MPR的能力,曲线下面积为0.85。CZT-SPECT确定MPR截止值为2.5用于检测PET异常MPR,敏感性、特异性和准确性分别为86%、73%和80%。通过区域MPR识别阻塞性CAD的曲线下面积,CZT-SPECT为0.83,PET为0.84(P =.90)。在CZT-SPECT中,区域MPR为2.1在识别阻塞性CAD的敏感性和特异性之间提供了最佳平衡。使用各自截止值时,CZT-SPECT和PET的诊断准确性相当(P =.62)。

结论

CZT-SPECT获得的充血MBF和MPR值高于Rb-PET成像测量的值,两种方法之间存在中等相关性。CZT-SPECT在识别阻塞性CAD方面显示出良好的诊断准确性。这些发现可能会鼓励使用这项新技术进行更好的风险分层和患者管理。