使用99mTc-替曲膦通过碲化镉锌探测器门控单光子发射计算机断层显像评估的绝对心肌血流量和血流储备:与13N-氨正电子发射断层显像的直接比较

Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.

作者信息

Nkoulou Rene, Fuchs Tobias A, Pazhenkottil Aju P, Kuest Silke M, Ghadri Jelena R, Stehli Julia, Fiechter Michael, Herzog Bernhard A, Gaemperli Oliver, Buechel Ronny R, Kaufmann Philipp A

机构信息

Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University of Zurich, Zurich, Switzerland.

Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University of Zurich, Zurich, Switzerland

出版信息

J Nucl Med. 2016 Dec;57(12):1887-1892. doi: 10.2967/jnumed.115.165498. Epub 2016 Jun 30.

Abstract

UNLABELLED

Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET.

METHODS

Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress-rest myocardial perfusion imaging (MPI) by Tc-tetrofosmin CZT SPECT and N-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve.

RESULTS

Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77-1.00] vs. 0.92 [IQR, 0.78-1.06] mL/g/min; P = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00-1.26] vs. 2.06 [IQR, 1.48-2.56] mL/g/min; P < 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13-1.52) by CZT and 2.36 (IQR, 1.57-2.71) by PET (P < 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%.

CONCLUSION

The estimation of absolute MBF index values by CZT SPECT MPI with Tc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with N-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.

摘要

未标注

包括碲锌镉(CZT)半导体探测器材料在内的单光子发射计算机断层扫描(SPECT)技术的最新进展可能为通过SPECT测量绝对心肌血流量(MBF)铺平道路。本研究的目的是比较用CZT SPECT相机与正电子发射断层扫描(PET)评估的人体中作为绝对MBF替代指标的钾摄取速率常数和心肌血流储备指数(MFRi)。

方法

对28例连续接受腺苷负荷 - 静息心肌灌注成像(MPI)的患者,通过锝 - 替曲膦CZT SPECT和N - 氨PET评估绝对MBF,并将MFR计算为充血状态下与静息MBF的比值。比较两种MPI方法的结果并计算相关系数。使用受试者工作特征曲线评估CZT MFRi预测定义为PET MFR小于2的异常MFR的诊断准确性。

结果

CZT和PET静息时的MBF中位数相当(0.89 [四分位间距(IQR),0.77 - 1.00] 对0.92 [IQR,0.78 - 1.06] mL/g/min;P = 无显著差异),而CZT负荷时的MBF显著低于PET(1.11 [IQR,1.00 - 1.26] 对2.06 [IQR,1.48 - 2.56] mL/g/min;P < 0.001)。这导致CZT的MFRi中位数为1.32(IQR,1.13 - 1.52),PET为2.36(IQR,1.57 - 2.71)(P < 0.001)。受试者工作特征曲线显示CZT MFRi的截断值为1.26,以预测异常的PET MFR,准确率为75%。

结论

用锝 - 替曲膦通过CZT SPECT MPI估计绝对MBF指数值在技术上是可行的,尽管充血状态下的值显著低于用N - 氨PET测得的值,导致MFR被大幅低估。然而,CZT MFRi可能具有诊断价值。