Weber Birte, Lackner Ina, Baur Meike, Fois Giorgio, Gebhard Florian, Marzi Ingo, Schrezenmeier Hubert, Relja Borna, Kalbitz Miriam
Department of Traumatology, Hand-, Plastic- and Reconstructive Surgery, Center of Surgery, University of Ulm, 89081 Ulm, Germany.
Institute of General Physiology, University of Ulm, 89081 Ulm, Germany.
J Clin Med. 2020 May 11;9(5):1421. doi: 10.3390/jcm9051421.
The aim of the study was to determine the effects of post-traumatically released High Mobility Group Box-1 protein (HMGB1) and extracellular histones on cardiomyocytes (CM). We also evaluated a therapeutic option to capture circulating histones after trauma, using a hemadsorption filter to treat CM dysfunction.
We evaluated cell viability, calcium handling and mitochondrial respiration of human cardiomyocytes in the presence of HMGB-1 and extracellular histones. In a translational approach, a hemadsorption filter was applied to either directly eliminate extracellular histones or to remove them from blood samples obtained from multiple injured patients.
Incubation of human CM with HMGB-1 or histones is associated with changes in calcium handling, a reduction of cell viability and a substantial reduction of the mitochondrial respiratory capacity. Filtrating plasma from injured patients with a hemadsorption filter reduces histone concentration ex vivo and in vitro, depending on dosage.
Danger associated molecular patterns such as HMGB-1 and extracellular histones impair human CM in vitro. A hemadsorption filter could be a therapeutic option to reduce high concentrations of histones.
本研究旨在确定创伤后释放的高迁移率族蛋白盒1(HMGB1)和细胞外组蛋白对心肌细胞(CM)的影响。我们还评估了一种治疗方案,即使用血液吸附滤器治疗CM功能障碍,以捕获创伤后的循环组蛋白。
我们在存在HMGB-1和细胞外组蛋白的情况下,评估了人类心肌细胞的细胞活力、钙处理和线粒体呼吸。在转化研究中,应用血液吸附滤器直接清除细胞外组蛋白或从多名受伤患者获得的血样中去除组蛋白。
用HMGB-1或组蛋白孵育人CM与钙处理变化、细胞活力降低和线粒体呼吸能力大幅降低有关。用血液吸附滤器过滤受伤患者的血浆可降低体内外组蛋白浓度,具体取决于剂量。
HMGB-1和细胞外组蛋白等与危险相关的分子模式在体外会损害人CM。血液吸附滤器可能是降低高浓度组蛋白的一种治疗选择。