3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, Italy.
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Italy.
J Cardiovasc Comput Tomogr. 2020 Nov-Dec;14(6):520-523. doi: 10.1016/j.jcct.2020.04.003. Epub 2020 Apr 11.
Multidetector computed tomography (MDCT) is currently the imaging technique of choice for the assessment of tricuspid valve (TV) annulus geometry and relationship with the right coronary artery (RCA). However, standardized protocols with a full 3D analysis are still lacking to plan percutaneous procedures for functional tricuspid regurgitation (FTR). A novel customized 4-dimensional tool based on MDCT data was developed and provided accurate information on TV annulus morphology (3D-perimeter, 2D-Area, maximum and minimum diameters, eccentricity index), function and distance to the RCA, crucial for patient selection of percutaneous TV procedures.
多排螺旋计算机断层扫描(MDCT)目前是评估三尖瓣(TV)瓣环几何形状和与右冠状动脉(RCA)关系的首选成像技术。然而,对于功能性三尖瓣反流(FTR)的经皮手术,仍然缺乏具有完整 3D 分析的标准化方案。我们开发了一种基于 MDCT 数据的新型定制 4 维工具,可提供有关 TV 瓣环形态(3D 周长、2D 面积、最大和最小直径、偏心指数)、功能和与 RCA 距离的准确信息,对于经皮 TV 手术的患者选择至关重要。