Suppr超能文献

穿透性角膜移植术后巩膜镜配戴:角膜曲率和光学的变化。

Scleral lens wear following penetrating keratoplasty: changes in corneal curvature and optics.

机构信息

Narayana Nethralaya, Bangalore, Karnataka, India.

Contact Lens and Visual Optics Laboratory, School of Optometry & Vision Science, Queensland University of Technology, Brisbane, Australia.

出版信息

Ophthalmic Physiol Opt. 2020 Jul;40(4):502-509. doi: 10.1111/opo.12693. Epub 2020 May 21.

Abstract

PURPOSE

Visual rehabilitation following penetrating keratoplasty is the primary indication for approximately 15% of all scleral lens fittings. Since corneal biomechanics are altered following penetrating keratoplasty, the aim of this study was to quantify changes in anterior corneal optics following short-term scleral lens wear in eyes with corneal grafts.

METHODS

Scheimpflug images were obtained before and after a period of scleral lens wear (mean 6.3 ± 1.4 h), from eyes that had previously undergone penetrating keratoplasty (10 eyes of nine participants, mean age 31 ± 9 years). Corneal power and thickness data were examined over the central 6 mm, including regional analyses of the central (0-3 mm) and the mid-peripheral cornea (3-6 mm annulus) using customised software to deterime corneal power vectors M (best fit sphere), J (90/180 astigmatism) and J (45/135 astigmatism). Anterior corneal aberrations were extracted using corneal elevation data.

RESULTS

Corneal power vector J increased following lens wear (by 0.22 ± 0.05 D, p = 0.003) across the central 6 mm, while M displayed regional variations following lens wear indicating larger changes further from the corneal centre (p = 0.004). The change in corneal power vector M was also correlated with the magnitude of central corneal swelling (r = 0.65, p = 0.04). The anterior corneal aberration terms of oblique astigmatism, hoirzontal coma, and spherical aberration also varied following lens wear (all p ≤ 0.01). The mean change in the corneal spherocylinder derived from the elevation data following lens wear was +0.14/-0.54 × 44 for a 6 mm corneal diameter.

CONCLUSIONS

Clinically significant alterations in anterior corneal topography and higher order aberrations were observed following short-term scleral lens wear in eyes that had undergone penetrating keratoplasty. Spherocylindrical changes were approximately double the magnitude and more oblique in orientation compared to previous reports of healthy eyes. Changes in corneal power vector M may be related to epithelial corneal oedema.

摘要

目的

穿透性角膜移植术后的视觉康复是所有巩膜镜配镜的主要适应证之一,约占 15%。由于穿透性角膜移植术后角膜生物力学发生改变,本研究旨在量化角膜移植术后短期内巩膜镜佩戴对眼前段角膜光学的影响。

方法

对 9 名参与者的 10 只眼(平均年龄 31±9 岁)进行了研究,这些参与者先前接受了穿透性角膜移植术,在佩戴巩膜镜(平均 6.3±1.4 小时)前后获得了 Scheimpflug 图像。使用定制软件检查中央 6mm 范围内的角膜屈光力和厚度数据,包括中央(0-3mm)和中周角膜(3-6mm 环)的区域分析,以确定角膜屈光力向量 M(最佳拟合球面)、J(90/180 散光)和 J(45/135 散光)。使用角膜高度数据提取前角膜像差。

结果

佩戴巩膜镜后角膜屈光力向量 J 在中央 6mm 范围内增加(增加 0.22±0.05 D,p=0.003),而 M 则显示出佩戴巩膜镜后的区域变化,表明离角膜中心越远变化越大(p=0.004)。角膜屈光力向量 M 的变化也与中央角膜肿胀的程度相关(r=0.65,p=0.04)。前角膜像差项斜散光、水平彗差和球差也随巩膜镜佩戴而改变(均 p≤0.01)。佩戴巩膜镜后,从高度数据得出的角膜等效球镜的平均变化为+0.14/-0.54×44,角膜直径为 6mm。

结论

穿透性角膜移植术后短期佩戴巩膜镜可观察到眼前段角膜形态和高阶像差的显著改变。与健康眼的先前报道相比,等效球镜的变化幅度大约是两倍,且更偏斜。角膜屈光力向量 M 的变化可能与上皮性角膜水肿有关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验