Suppr超能文献

评估各种二氧化碳激光设置对进行全层皮肤切口所需的激光束照射时间和次数以及激光诱导的组织伪影量的影响。

Evaluation of various carbon dioxide laser settings on the time and number of laser beam passes required to make a full-thickness skin incision and amount of laser-induced tissue artifact.

作者信息

Agulian Lori M, Mann F A, Middleton John R, Kim Dae Y

出版信息

Am J Vet Res. 2020 Jun;81(6):514-520. doi: 10.2460/ajvr.81.6.514.

Abstract

OBJECTIVE

To evaluate the time and number of laser beam passes required to make full-thickness skin incisions and extent of laser-induced tissue artifacts following use of a CO laser at various settings.

SAMPLE

24 skin specimens from six 5-month-old porcine carcasses.

PROCEDURES

4 full-thickness skin specimens were harvested from the flank regions of each carcass within 30 minutes after euthanasia and randomly assigned to 4 treatment groups. Three 5-cm-long incisions were made in each specimen with a CO laser (beam diameter, 0.4 mm) set to deliver a continuous wave of energy alone (groups 1 and 2) or in superpulse mode (groups 3 and 4) at 10 (groups 1 and 3) or 20 (groups 2 and 4) W of power. The time and number of passes required to achieve a full-thickness incision were recorded, and extent of laser-induced tissue artifact (as determined by histologic evaluation) was compared among the 4 groups.

RESULTS

Mean time required to make a full-thickness skin incision for groups 2 and 4 (power, 20 W) was significantly less than that for groups 1 and 3 (power, 10 W). Mean number of passes was lowest for group 2 (continuous wave at 20 W). Extent of laser-induced tissue artifact was greatest for group 4 (superpulse mode at 20 W).

CONCLUSIONS AND CLINICAL RELEVANCE

Results provided preliminary information regarding use of CO lasers to make skin incisions in veterinary patients. In vivo studies are necessary to evaluate the effect of various CO laser settings on tissue healing and patient outcome.

摘要

目的

评估在不同设置下使用CO激光进行全层皮肤切口所需的时间和激光束照射次数,以及激光诱导的组织伪像程度。

样本

来自6头5月龄猪尸体的24个皮肤标本。

程序

在安乐死后30分钟内,从每具尸体的侧腹区域采集4个全层皮肤标本,并随机分配到4个治疗组。使用CO激光(光束直径0.4mm)在每个标本上制作3个5cm长的切口,激光设置为单独发射连续能量波(第1组和第2组)或超脉冲模式(第3组和第4组),功率分别为10W(第1组和第3组)或20W(第2组和第4组)。记录实现全层切口所需的时间和照射次数,并比较4组之间激光诱导的组织伪像程度(通过组织学评估确定)。

结果

第2组和第4组(功率20W)进行全层皮肤切口所需的平均时间显著少于第1组和第3组(功率10W)。第2组(20W连续波)的平均照射次数最低。第4组(20W超脉冲模式)的激光诱导组织伪像程度最大。

结论及临床意义

结果提供了关于在兽医患者中使用CO激光进行皮肤切口的初步信息。有必要进行体内研究以评估各种CO激光设置对组织愈合和患者预后的影响。