Suppr超能文献

采取双管齐下的方法降低新生儿重症监护病房的噪声水平。

A two-pronged approach to reduce noise levels in the neonatal intensive care unit.

机构信息

Department of Pediatrics, School of Rehabilitation Therapy, Queen's University, Kingston, Ontario, Canada.

Department of Pediatrics, School of Rehabilitation Therapy, Queen's University, Kingston, Ontario, Canada.

出版信息

Early Hum Dev. 2020 Jul;146:105073. doi: 10.1016/j.earlhumdev.2020.105073. Epub 2020 May 13.

Abstract

OBJECTIVES

The aim of this study was to assess the efficacy of a visual noise feedback system and "quiet time" in reducing noise levels in the neonatal intensive care unit (NICU).

DESIGN

A prospective cross-sectional study was performed in a combined level II/III NICU at a Canadian tertiary care hospital. Noise levels were recorded continuously for three weeks without and then three weeks with visual noise feedback system. Noise levels were compared after one year of using visual feedback, and subsequently with the addition of two "quiet times."

RESULTS

Visual feedback reduced noise levels from 54.2 dB (95% CI 53.8-54.7 dB) to 49.4 dB (95% CI 48.9-49.8 dB; P < 0.0001) and increased the amount of time spent under 45 dB from 0 to 25% (P < 0.0001) after three weeks of use. However, this effect was not sustained at one year of visual feedback, with noise levels at 54.7 dB (95% CI 54.5-55.0 dB, P = 0.55). Quiet Time did not further reduce daily noise in the NICU (average noise levels 54.7, 95% CI 54.4-55.0 dB, P = 0.836).

CONCLUSIONS

While visual noise feedback system reduced noise levels in the short term, these effects were not sustainable at one year and could not be remediated with the addition of a Quiet Time initiative. Continuing education regarding the detrimental effects of noise is paramount to ensure persistent noise reduction in the NICU.

摘要

目的

本研究旨在评估视觉噪声反馈系统和“安静时间”在降低新生儿重症监护病房(NICU)噪声水平方面的效果。

设计

在加拿大一家三级保健医院的综合二级/三级 NICU 中进行了前瞻性横断面研究。在没有视觉噪声反馈系统的情况下连续记录噪声水平三周,然后在使用视觉噪声反馈系统的情况下记录三周。在使用视觉反馈一年后,以及随后增加两个“安静时间”后,比较了噪声水平。

结果

视觉反馈将噪声水平从 54.2dB(95%CI 53.8-54.7dB)降低至 49.4dB(95%CI 48.9-49.8dB;P<0.0001),并将低于 45dB 的时间比例从 0 增加到 25%(P<0.0001),使用三周后。然而,在使用视觉反馈一年后,这种效果并未持续,噪声水平为 54.7dB(95%CI 54.5-55.0dB,P=0.55)。安静时间并没有进一步降低 NICU 的日常噪声(平均噪声水平为 54.7dB,95%CI 54.4-55.0dB,P=0.836)。

结论

虽然视觉噪声反馈系统在短期内降低了噪声水平,但这些效果在一年后并不持久,并且添加安静时间倡议也无法缓解。持续进行有关噪声有害影响的教育对于确保 NICU 持续降低噪声至关重要。