Suppr超能文献

猫血液中生物胺神经递质水平的 EDTA 样本检测不可靠。

Unreliability of EDTA samples for measuring bioamine neurotransmitter levels in cats.

机构信息

Department of Medical Clinics, Faculty of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil.

Nephrology Department, Faculty of Medicine, São Paulo Federal University, São Paulo, Brazil.

出版信息

J Feline Med Surg. 2021 Feb;23(2):190-193. doi: 10.1177/1098612X20924916. Epub 2020 Jun 1.

Abstract

OBJECTIVES

The aim of this study was to assess the reliability of an EDTA-based method for measuring cat blood bioamines.

METHODS

Test 1 involved collecting blood samples from seven university laboratory cats. The samples were transferred to EDTA, heparin and plain tubes to determine concentrations of four bioamines (serotonin, dopamine, epinephrine [adrenaline] and norepinephrine [noradrenaline]). Correlation of measurements performed on EDTA plasma, with those performed on heparinized plasma or serum were assessed by intraclass correlation coefficients (ICCs). In test 2, blood samples from five owned cats were collected and stored in EDTA tubes and divided between duplicate Eppendorf tubes labeled as different cats for blinding purposes and analyzed independently for the same four bioamines as in test 1. Reliability of concentration determination for these duplicates was assessed by ICCs and coefficients of variation (CVs).

RESULTS

In test 1, there was no significant correlation between the EDTA plasma serotonin and serum serotonin concentrations. There was also no significant correlation between EDTA plasma and heparin plasma concentrations for either epinephrine or norepinephrine. There was a statistically significant but weak correlation between EDTA plasma and heparin plasma dopamine concentrations. In test 2, there was no correlation for repeat-analyzed serotonin and epinephrine concentrations. Although there were statistically significant correlations for dopamine and norepinephrine, CVs for each analyte were in excess of 30%.

CONCLUSIONS AND RELEVANCE

Before any further attempt is made to measure and report on neurotransmitter concentrations in domestic cats, it is essential that the robustness of the methodology is carefully validated and the data presented.

摘要

目的

本研究旨在评估基于 EDTA 的方法测量猫血液生物胺的可靠性。

方法

试验 1 包括从 7 只大学实验室猫采集血液样本。将样本转移至 EDTA、肝素和普通管中,以确定四种生物胺(血清素、多巴胺、肾上腺素[去甲肾上腺素]和去甲肾上腺素[去甲肾上腺素])的浓度。通过组内相关系数(ICC)评估 EDTA 血浆测量值与肝素化血浆或血清测量值之间的相关性。在试验 2 中,从 5 只家养猫采集血液样本并储存在 EDTA 管中,分为两份,分别放入标记为不同猫的重复的 Eppendorf 管中,用于盲法目的,并独立分析与试验 1 相同的四种生物胺。通过 ICC 和变异系数(CV)评估这些重复的浓度测定的可靠性。

结果

在试验 1 中,EDTA 血浆中血清素和血清中血清素浓度之间无显著相关性。EDTA 血浆和肝素血浆中肾上腺素或去甲肾上腺素浓度之间也无显著相关性。EDTA 血浆和肝素血浆多巴胺浓度之间存在统计学上显著但较弱的相关性。在试验 2 中,重复分析的血清素和肾上腺素浓度无相关性。尽管多巴胺和去甲肾上腺素存在统计学上显著的相关性,但每个分析物的 CV 均超过 30%。

结论和相关性

在进一步尝试测量和报告家猫神经递质浓度之前,必须仔细验证方法的稳健性并提供数据。

相似文献

7
Anticoagulant-dependent in vitro hemagglutination in a cat.
Vet Clin Pathol. 2009 Jun;38(2):194-200. doi: 10.1111/j.1939-165X.2009.00114.x. Epub 2009 Mar 12.

本文引用的文献

3
Hormones as indicators of stress.作为压力指标的激素。
Domest Anim Endocrinol. 2002 Jul;23(1-2):67-74. doi: 10.1016/s0739-7240(02)00146-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验