Suppr超能文献

超声清洁对充满预混生物陶瓷根管封闭剂的椭圆形根管中纤维桩粘结强度的影响。

Effect of ultrasonic cleaning on the bond strength of fiber posts in oval canals filled with a premixed bioceramic root canal sealer.

作者信息

Peña Bengoa Fernando, Magasich Arze Maria Consuelo, Macchiavello Noguera Cristobal, Moreira Luiz Felipe Nunes, Kato Augusto Shoji, Bueno Carlos Eduardo Da Silveira

机构信息

Department of Endodontics, Faculty of Dentistry, Universidad Andres Bello, Viña del Mar, Chile.

Private Practice, Viña del Mar, Chile.

出版信息

Restor Dent Endod. 2020 Feb 20;45(2):e19. doi: 10.5395/rde.2020.45.e19. eCollection 2020 May.

Abstract

OBJECTIVE

This study aimed to evaluate the effect of ultrasonic cleaning of the intracanal post space on the bond strength of fiber posts in oval canals filled with a premixed bioceramic (Bio-C Sealer [BIOC]) root canal sealer.

MATERIALS AND METHODS

Fifty premolars were endodontically prepared and divided into 5 groups ( = 10), based on the type of root canal filling material used and the post space cleaning protocol. A1: gutta-percha + AH Plus (AHP) and post space preparation with ultrasonic cleaning, A2: gutta-percha + BIOC and post space preparation with ultrasonic cleaning, B1: gutta-percha + AHP and post space preparation, B2: gutta-percha + BIOC and post space preparation, C: control group. Fiber posts were cemented with a self-adhesive luting material, and 1 mm thick slices were sectioned from the middle and cervical third to evaluate the remaining filling material microscopically. The samples were subjected to a push-out test to analyze the bond strength of the fiber post, and the results were analyzed with the Shapiro-Wilk, Bonferroni, Kruskal-Wallis, and Mann-Whitney tests ( < 0.05). Failure modes were evaluated using optical microscopy.

RESULTS

The results showed that the fiber posts cemented in canals sealed with BIOC had lower bond strength than those sealed with AHP. The ultrasonic cleaning of the post space improved the bond strength of fiber posts in canals sealed with AHP, but not with BIOC.

CONCLUSIONS

BIOC decreased the bond strength of fiber posts in oval canals, regardless of ultrasonic cleaning.

摘要

目的

本研究旨在评估超声清洁根管内桩道空间对预混生物陶瓷(Bio-C封闭剂[BIOC])根管封闭剂充填的椭圆形根管中纤维桩粘结强度的影响。

材料与方法

选取50颗前磨牙进行根管预备,根据所使用的根管充填材料类型和桩道空间清洁方案分为5组(每组n = 10)。A1组:牙胶尖+AH Plus(AHP),超声清洁桩道空间;A2组:牙胶尖+BIOC,超声清洁桩道空间;B1组:牙胶尖+AHP,常规预备桩道空间;B2组:牙胶尖+BIOC,常规预备桩道空间;C组:对照组。使用自粘结粘结材料粘结纤维桩,从牙根中部和颈部三分之一处切取1 mm厚的切片,显微镜下评估剩余充填材料。对样本进行推出试验以分析纤维桩的粘结强度,并采用Shapiro-Wilk检验、Bonferroni检验、Kruskal-Wallis检验和Mann-Whitney检验分析结果(P < 0.05)。使用光学显微镜评估失败模式。

结果

结果显示,用BIOC封闭的根管中粘结的纤维桩的粘结强度低于用AHP封闭的根管中的纤维桩。桩道空间的超声清洁提高了用AHP封闭的根管中纤维桩的粘结强度,但对用BIOC封闭的根管中的纤维桩无效。

结论

无论是否进行超声清洁,BIOC都会降低椭圆形根管中纤维桩的粘结强度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2e2c/7239684/0a643255053a/rde-45-e19-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验