Suppr超能文献

使用主观和客观技术评估马来西亚一所私立大学学生的调节幅度。

Amplitude of Accommodation among Students of a Malaysian Private University as Assessed Using Subjective and Objective Techniques.

作者信息

Majumder Chiranjib, Afnan Hakim

机构信息

School of Optometry, Faculty of Medicine and Health Sciences, UCSI University, Kuala Lumpur, Malaysia.

出版信息

Korean J Ophthalmol. 2020 Jun;34(3):219-226. doi: 10.3341/kjo.2019.0138.

Abstract

PURPOSE

The purpose of the study was to establish baseline data for amplitude of accommodation (AA) measured using both subjective and objective techniques in students at a private Malaysian university.

METHODS

This cross-sectional study was conducted including 34 healthy participants with a mean age of 22.26 ± 1.88 years. AA was measured using dynamic retinoscopy and the push-up, pull-away, modified push-up, and minus-lens techniques.

RESULTS

The mean AA scores for the push-up, pull-away, minus-lens, and modified push-up techniques and dynamic retinoscopy were 11.38 ± 2.03, 10.35 ± 1.64, 9.24 ± 1.18, 8.26 ± 1.44, and 7.2 ± 1.0 diopters, respectively. No AA measurements showed significant difference among ethnicities (Chinese, Malay, and Indian). This study suggested that AA obtained using push-up ( = 0.005) and pull-away ( = 0.017) methods and dynamic retinoscopy ( = 0.041) were significantly different according to sex. No significant difference was observed in AA for the minus-lens ( = 0.051) and modified push-up ( = 0.216) techniques by sex. A moderately negative correlation was found between AA and age for the push-up ( = -0.434, = 0.010), pull-away ( = -0.412, = 0.016), and minus-lens ( = -0.509, = 0.002) techniques and dynamic retinoscopy ( = -0.497, = 0.003). A weak negative correlation was found between age and AA measured using a modified push-up technique ( = -0.393, = 0.022).

CONCLUSIONS

Mean AA was highest for the push-up technique, followed by the pull-away technique, the minus-lens technique, the modified push up technique, and dynamic retinoscopy. The push-up and pull-away methods and dynamic retinoscopy showed a significant difference in measurement of AA between sexes.

摘要

目的

本研究的目的是为马来西亚一所私立大学的学生使用主观和客观技术测量调节幅度(AA)建立基线数据。

方法

本横断面研究纳入了34名健康参与者,平均年龄为22.26±1.88岁。使用动态检影法以及上推法、后拉法、改良上推法和负透镜法测量AA。

结果

上推法、后拉法、负透镜法、改良上推法和动态检影法的平均AA值分别为11.38±2.03、10.35±1.64、9.24±1.18、8.26±1.44和7.2±1.0屈光度。各民族(华人、马来人和印度人)之间的AA测量值无显著差异。本研究表明,根据性别,使用上推法(P = 0.005)、后拉法(P = 0.017)和动态检影法(P = 0.041)测得的AA有显著差异。按性别,负透镜法(P = 0.051)和改良上推法(P = 0.216)测量的AA无显著差异。上推法(r = -0.434,P = 0.010)、后拉法(r = -0.412,P = 0.016)、负透镜法(r = -0.509,P = 0.002)和动态检影法(r = -0.497,P = 0.003)测量的AA与年龄之间存在中度负相关。使用改良上推法测量的年龄与AA之间存在弱负相关(r = -0.393,P = 0.022)。

结论

上推法的平均AA最高,其次是后拉法、负透镜法、改良上推法和动态检影法。上推法、后拉法和动态检影法在两性AA测量上存在显著差异。

相似文献

7
Objective and subjective assessment of accommodative insufficiency.调节不足的客观和主观评估。
Optom Vis Sci. 2024 Jan 1;101(1):44-54. doi: 10.1097/OPX.0000000000002097. Epub 2024 Jan 8.
8
Comparing measurement techniques of accommodative amplitudes.比较调节幅度的测量技术。
Indian J Ophthalmol. 2014 Jun;62(6):683-7. doi: 10.4103/0301-4738.126990.
10
Comparing accommodative function between the dominant and non-dominant eye.比较主导眼和非主导眼的调节功能。
Graefes Arch Clin Exp Ophthalmol. 2014 Mar;252(3):509-14. doi: 10.1007/s00417-013-2480-7. Epub 2013 Oct 26.

本文引用的文献

1
Visual efficiency among teenaged athletes and non-athletes.青少年运动员与非运动员的视觉效率
Int J Ophthalmol. 2017 Sep 18;10(9):1460-1464. doi: 10.18240/ijo.2017.09.20. eCollection 2017.
2
Amplitude of accommodation in an 11- to 17-year-old Iranian population.11至17岁伊朗人群的调节幅度。
Clin Exp Optom. 2017 Mar;100(2):162-166. doi: 10.1111/cxo.12431. Epub 2016 Aug 22.
4
Comparing measurement techniques of accommodative amplitudes.比较调节幅度的测量技术。
Indian J Ophthalmol. 2014 Jun;62(6):683-7. doi: 10.4103/0301-4738.126990.
5
Population-based study of presbyopia in Shahroud, Iran.伊朗沙赫鲁德基于人群的远视研究。
Clin Exp Ophthalmol. 2012 Dec;40(9):863-8. doi: 10.1111/j.1442-9071.2012.02799.x. Epub 2012 Jun 4.
6
Investigation of amplitude of accommodation among Ghanaian school children.加纳学童调节幅度的调查。
Clin Exp Optom. 2012 Mar;95(2):187-91. doi: 10.1111/j.1444-0938.2011.00692.x. Epub 2012 Jan 19.
8
Critical subjective measurement of amplitude of accommodation.
Optom Vis Sci. 1994 Nov;71(11):699-706. doi: 10.1097/00006324-199411000-00005.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验