Doppler optical coherence tomography (DOCT) flowmeter can be used to measure retinal blood flow (RBF) parameters, including vessel diameter, blood velocity, and the absolute value of RBF within 2.0 s. We investigated the RBF parameters in eyes with branch retinal vein occlusion (BRVO) using a DOCT flowmeter.
Seventeen patients with unilateral BRVO were enrolled. All subjects underwent comprehensive ophthalmologic examinations. The RBF parameters were assessed from three veins, i.e., (1) an occluded vein, (2) a non-occluded vein in the BRVO eyes, and (3) an equivalent (superior or inferior) vein in the fellow eye (non-affected vein), using prototype DOCT flowmeter (Topcon, Tokyo, Japan). Moreover, the correlation between RBF parameters and the best corrected visual acuity (BCVA) was examined. We investigated the correlation between (1) the RBF parameters and the time from the initial visit, (2) the RBF parameters and the time from the last injection, and (3) the RBF parameters and the number of anti-vascular endothelial growth factor injections (VEGF).
The diameter of the occluded vein (95.9 ± 24.7 µm) was smaller than that of the non-occluded vein (127.9 ± 23.7 µm) and that of the healthy veins (116.4 ± 13.9 µm). The RBF was lower in the occluded veins (4.7 ± 3.7 µL/min) than that in the non-occluded veins (10.3 ± 5.1 µL/min; < 0.01) and in the fellow eyes (8.6 ± 4.0 µL/min; = 0.013). In contrast, the blood velocity was not significantly different among the three types of veins. BCVA was correlated with the diameter of the occluded vein (ρ = 0.711, = 0.001) but not with the RBF and blood velocity. The time from the initial visit, the time from the last injection, and the total number of anti-VEGF injections were not associated with any RBF parameters on the occluded vein.
The RBF was significantly lower in the occluded veins than that in the other veins, and the diameter of the occluded vein was significantly smaller than that of the other veins in patients with BRVO. However, neither the time from the initial visit, nor the time from the last injection, nor the number of anti-VEGF injections were correlated with the RBF parameters on the occluded vein.
多普勒光学相干断层扫描(DOCT)流量计可用于测量视网膜血流(RBF)参数,包括血管直径、血流速度以及2.0秒内RBF的绝对值。我们使用DOCT流量计研究了视网膜分支静脉阻塞(BRVO)患者的RBF参数。
纳入17例单侧BRVO患者。所有受试者均接受了全面的眼科检查。使用原型DOCT流量计(日本东京拓普康公司)从三条静脉评估RBF参数,即:(1)阻塞静脉;(2)BRVO患眼中的非阻塞静脉;(3)对侧眼(未受影响静脉)中的对应(上或下)静脉。此外,还检查了RBF参数与最佳矫正视力(BCVA)之间的相关性。我们研究了(1)RBF参数与初诊时间之间的相关性;(2)RBF参数与上次注射时间之间的相关性;(3)RBF参数与抗血管内皮生长因子注射次数(VEGF)之间的相关性。
阻塞静脉的直径(95.9±24.7μm)小于非阻塞静脉(127.9±23.7μm)和健康静脉(116.4±13.9μm)。阻塞静脉的RBF(4.7±3.7μL/min)低于非阻塞静脉(10.3±5.1μL/min;P<0.01)和对侧眼(8.6±4.0μL/min;P=0.013)。相比之下,三种类型静脉之间的血流速度无显著差异。BCVA与阻塞静脉的直径相关(ρ=0.711,P=0.001),但与RBF和血流速度无关。初诊时间、上次注射时间以及抗VEGF注射的总数与阻塞静脉的任何RBF参数均无关联。
BRVO患者阻塞静脉的RBF显著低于其他静脉,且阻塞静脉的直径显著小于其他静脉。然而,初诊时间、上次注射时间以及抗VEGF注射次数均与阻塞静脉的RBF参数无关。