Martin Samuel Joseph, Htoo Hser Eh, Hser Nay, Arnold Robert W
Alaska Blind Child Discovery, Anchorage, AK, USA.
Jungle School of Medicine Kawthoolei, Karen State, Burma (Myanmar).
Clin Ophthalmol. 2020 May 25;14:1427-1435. doi: 10.2147/OPTH.S251451. eCollection 2020.
Photoscreeners provide valid, cost-effective early detection of amblyopia risk factors; however, they require proper illumination, flash intensity, pupil dilation and patient cooperation. The Kaleidos case for the 2WIN infrared photoscreener fixes focal distance, decreases luminance and provides electric power. GoCheck Kids (GCK) has developed a flash-concentrating case for the Apple iPhone 7 Plus smartphone to reduce exposure time.
In remote Burmese and urban Alaskan clinics, Kaleidos and GCK were used before a confirmatory eye examination using 2013 AAPOS uniform guidelines validation, including some older patients. 2WIN refraction was compared to a cycloplegic examination using J0 and J45 vector transformation.
In total, 48 Burmese patients and 114 Alaskan patients aged 8±6 years were evaluated utilizing 2013 amblyopia risk factor guidelines. Kaleidos, with 13 Burmese inconclusives, had a sensitivity of 84%, specificity of 65% and positive predictive value (PPV) of 63%. GCK, with only six inconclusives, had a sensitivity of 63%, specificity of 83% and PPV of 73%, with sensitivity improving to 74% with central expert interpretation. Kaleidos closely matched cycloplegic refraction, with intraclass correlations of 0.47 for J0 vector and 0.57 for J45 vector. The protective cases provided clearer images and better pupil dilation than similar devices without cases.
Both devices detected amblyopia risk factors well. GCK gave fewer inconclusive results even with the Asian eyelid configuration, while Kaleidos matched sphere and cylinder refraction. The specialized housing enhanced the performance of the 2WIN and GCK photoscreeners, improving the speed and reliability of amblyopia screening and refraction, even in populous and luminous locations.
NCT04068129.
电脑验光仪能有效、经济地早期检测弱视风险因素;然而,它们需要适当的照明、闪光强度、瞳孔散大及患者配合。2WIN红外电脑验光仪的Kaleidos保护套可固定焦距、降低亮度并提供电力。GoCheck Kids(GCK)为苹果iPhone 7 Plus智能手机开发了一种闪光聚光保护套以减少曝光时间。
在缅甸偏远地区和阿拉斯加城市的诊所,在使用2013年美国儿科学会斜视与小儿眼科协会(AAPOS)统一指南进行确认性眼科检查之前,使用了Kaleidos和GCK,其中包括一些老年患者。将2WIN验光结果与使用J0和J45矢量转换的睫状肌麻痹验光检查结果进行比较。
总共对48名年龄8±6岁的缅甸患者和114名阿拉斯加患者按照2013年弱视风险因素指南进行了评估。Kaleidos有13例缅甸患者结果不确定,其灵敏度为84%,特异性为65%,阳性预测值(PPV)为63%。GCK只有6例结果不确定,其灵敏度为63%,特异性为83%,PPV为73%;经中心专家解读后,灵敏度提高到74%。Kaleidos与睫状肌麻痹验光结果密切匹配,J0矢量组内相关性为0.47 J45矢量组内相关性为0.57。与没有保护套的类似设备相比,这两种保护套能提供更清晰的图像和更好的瞳孔散大效果。
两种设备都能很好地检测弱视风险因素。即使对于亚洲人眼睑结构,GCK得出不确定结果的情况更少,而Kaleidos在球镜和柱镜验光方面与之匹配。这种专用外壳提高了2WIN和GCK电脑验光仪的性能,即使在人口密集和光线充足的地方,也提高了弱视筛查和验光的速度及可靠性。
NCT04068129