van Waart Hanna, Harris Richard J, Gant Nicholas, Vrijdag Xavier Ce, Challen Craig J, Lawthaweesawat Chanrit, Mitchell Simon J
Department of Anaesthesiology, University of Auckland, Auckland, New Zealand.
MedSTAR Emergency Medical Retrieval Service, Adelaide, Australia.
Diving Hyperb Med. 2020 Jun 30;50(2):121-129. doi: 10.28920/dhm50.2.121-129.
In 2018 12 children and one adult were anaesthetised before being extricated through over a kilometre of flooded cave in Thailand. Full face dive masks (FFMs) putatively capable of maintaining constant positive airway pressure (CPAP) were employed. Here we describe the anaesthetic intervention and investigate the CPAP capability of the FFM.
Pressure was measured inside and outside the Interspiro Divator FFM during 10 tidal and 10 vital capacity breaths in divers at the surface and submerged with the mask deployed on open-circuit scuba (10 divers); and a closed-circuit rebreather (five divers). Relative in-mask pressure was calculated as the difference between inside and outside pressures. We also measured the in-mask pressure generated by activation of the second stage regulator purge valve in open-circuit mode.
When submerged in open-circuit mode the mean relative in-mask pressure remained positive in normal tidal breathing (inhalation 0.6 kPa [95% CI 0.3-0.9]; exhalation 1.1 [0.8-1.4]) and vital capacity breathing (inhalation 0.8 [0.4-1.1]; exhalation 1.2 [0.9-1.4]). As expected, the relative in-mask pressure was predominantly negative when used on closed-circuit with back mounted counter-lungs due to a negative static lung load. Mean in-mask pressure during purge valve operation was 3.99 kPa (approximately equal to 40 cmH2O) (range: 2.56 to 5.3 kPa).
The CPAP function of the Interspiro Divator FFM works well configured with open-circuit scuba. This may have contributed to the success of the Thailand cave rescue. Caution is required in generalising this success to other diving scenarios.
2018年,12名儿童和1名成人在泰国一处被洪水淹没、长达一公里多的洞穴中被解救出来之前接受了麻醉。使用了据信能够维持持续气道正压(CPAP)的全面罩潜水面罩(FFM)。在此,我们描述麻醉干预措施,并研究FFM的CPAP能力。
在水面和水下的潜水员进行10次潮气量呼吸和10次肺活量呼吸时,测量Interspiro Divator FFM内外的压力,面罩通过开路水肺潜水装置(10名潜水员)和闭路再呼吸器(5名潜水员)展开。面罩内相对压力计算为内外压力之差。我们还测量了在开路模式下激活二级调节器冲洗阀时产生的面罩内压力。
在开路模式下潜水时,正常潮气量呼吸(吸气0.6 kPa [95% CI 0.3 - 0.9];呼气1.1 [0.8 - 1.4])和肺活量呼吸(吸气0.8 [0.4 - 1.1];呼气1.2 [0.9 - 1.4])时,面罩内平均相对压力保持为正。正如预期的那样,由于静态肺负荷为负,在闭路且配备背部储气囊的情况下使用时,面罩内相对压力主要为负。冲洗阀操作期间的面罩内平均压力为3.99 kPa(约等于40 cmH2O)(范围:2.56至5.3 kPa)。
Interspiro Divator FFM的CPAP功能在与开路水肺潜水装置配置时运行良好。这可能促成了泰国洞穴救援行动的成功。将此成功经验推广到其他潜水场景时需谨慎。