Lee Eun Jeong, Kim Ji Young, Park Jung Mi, Song Bong-Il, Choi Hongyoon, Shim Hye-Kyeong, Park Hey Lim, Lee Ho-Young, Lee Kyung Jae, Yoon Joon-Kee, Seo Seongho, Kim Seong Min, Park Soo Bin, Cho Young Seok, Kim Seong Hoon
Department of Nuclear Medicine, Seoul Medical Center, Seoul, Republic of Korea.
Department of Nuclear Medicine, Hanyang University Guri Hospital, Guri-si, Republic of Korea.
Nucl Med Mol Imaging. 2020 Jun;54(3):139-146. doi: 10.1007/s13139-020-00644-9. Epub 2020 Jun 1.
Single-photon emission computed tomography/computed tomography (SPECT/CT) is an advanced hybrid nuclear medicine technology that generates both functional and anatomical images in a single study. As utilization of SPECT/CT in Korea has been increasing, the purpose of this study was to survey its application of cardiac and skeletal SPECT/CT imaging for protocol optimization.
We surveyed CT protocols established for cardiac and skeletal SPECT/CT. We searched the guidelines for the CT protocols for SPECT/CT and reviewed the literature recently published.
Among 36 hybrid SPECT scanners equipped with four or more multi-channel detector CTs (MDCTs), 18 scanners were used to perform cardiac studies at both very low current CT (30-80 mA; 11.1%) and ultra-low current CT (13-30 mA; 88.9%). Among the 33 canners, very low current (≤ 80 mA) CT or low current CT (80-130 mA) was used in 23.5%, and 41.8% for spine disorders, and in 36.4% or 30.3% for foot/ankle disorders, respectively. In the CT reconstructions, slice thickness of 5 mm for cardiac studies was most commonly used (94.4%); thinner slices (0.6-1.0 mm) for spine and foot/ankle studies were used in 24.2% and 45.5%, respectively. We also reviewed the international guidelines.
The results and current recommendations will be helpful for optimizing CT protocols for SPECT/CT. Optimization of SPECT/CT protocols will be required for generating the proper strategy for the specific lesions and clinical purpose.
单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)是一种先进的混合核医学技术,可在一次检查中生成功能图像和解剖图像。随着韩国SPECT/CT的使用不断增加,本研究的目的是调查其在心脏和骨骼SPECT/CT成像中的应用,以优化检查方案。
我们调查了为心脏和骨骼SPECT/CT制定的CT检查方案。我们搜索了SPECT/CT的CT检查方案指南,并查阅了最近发表的文献。
在36台配备四个或更多多通道探测器CT(MDCT)的混合SPECT扫描仪中,18台扫描仪用于在极低电流CT(30 - 80 mA;11.1%)和超低电流CT(13 - 30 mA;88.9%)下进行心脏检查。在33台扫描仪中,极低电流(≤ 80 mA)CT或低电流CT(80 - 130 mA)分别用于23.5%的脊柱疾病检查和41.8%的脊柱疾病检查,以及36.4%或30.3%的足/踝疾病检查。在CT重建中,心脏检查最常用的切片厚度为5 mm(94.4%);脊柱和足/踝检查分别有24.2%和45.5%使用了更薄的切片(0.6 - 1.0 mm)。我们还查阅了国际指南。
研究结果和当前建议将有助于优化SPECT/CT的CT检查方案。为针对特定病变和临床目的制定合适的策略,需要优化SPECT/CT检查方案。