Suppr超能文献

正常犬基础泪液和反射性泪液的渗透压

Osmolarity of basal and reflex tears of normal dogs.

作者信息

Lamkin Irini D, Zimmerman Kelli L, Smith Fleming Kathryn M, Martins Bianca C

机构信息

Veterinary Clinical Medicine Department, College of Veterinary Medicine, University of Illinois - Champaign, Urbana, IL, USA.

出版信息

Vet Ophthalmol. 2020 Jul;23(4):747-753. doi: 10.1111/vop.12798. Epub 2020 Jun 25.

Abstract

OBJECTIVE

To compare basal and reflex tear osmolarity in healthy dogs and to evaluate for correlation among tear film osmolarity, tear production, and tear fern pattern.

ANIMALS STUDIED

The population consisted of 22 healthy adult dogs.

PROCEDURES

Reflex tear osmolarity was measured in both eyes using the I-PEN  VET osmometer 30 minutes following the Schirmer tear test (STT-1) measurement. Subsequently, two minutes following topical anesthetic application, the lacrimal lake and conjunctival fornices were dried, and 3 minutes later, basal tear osmolarity was measured. Tears were extracted from the dye-free STT-1 strip by centrifugation, placed on a glass slide, and the ferning pattern was determined by light microscopy. Comparisons between basal and reflex tears were performed with one-way ANOVA. Correlations between tear osmolarity, STT-1, and tear ferning were verified by Pearson's correlation coefficient.

RESULTS

No statistical difference was found between right and left eyes for STT-1, tear fern pattern, and osmolarity of reflex or basal tears (P < .05). There was no statistical difference between osmolarity of basal and reflex tears among individuals (P < .05). No correlation was detected between tear fern pattern and osmolarity of reflex tears. A weak positive correlation was detected between STT-1 values and osmolarity of reflex, but not basal tears.

CONCLUSIONS

The osmolarity of basal tears did not differ from that of reflex tears. A positive weak correlation exists between tear production and osmolarity of reflex tears. No correlation was detected between tear osmolarity measured by handheld osmometer and tear ferning.

摘要

目的

比较健康犬的基础泪液和反射性泪液渗透压,并评估泪膜渗透压、泪液分泌量和泪液蕨类样形态之间的相关性。

研究动物

研究对象为22只健康成年犬。

方法

在进行Schirmer泪液试验(STT-1)测量30分钟后,使用I-PEN VET渗透压计测量双眼的反射性泪液渗透压。随后,在局部应用麻醉剂2分钟后,将泪湖和结膜穹窿擦干,3分钟后测量基础泪液渗透压。通过离心从无染料的STT-1试纸条中提取泪液,置于载玻片上,用光学显微镜确定蕨类样形态。基础泪液和反射性泪液之间的比较采用单因素方差分析。泪液渗透压、STT-1和泪液蕨类样形态之间的相关性通过Pearson相关系数进行验证。

结果

STT-1、泪液蕨类样形态以及反射性或基础泪液的渗透压在左右眼之间均未发现统计学差异(P < 0.05)。个体之间基础泪液和反射性泪液的渗透压没有统计学差异(P < 0.05)。未检测到泪液蕨类样形态与反射性泪液渗透压之间的相关性。检测到STT-1值与反射性泪液渗透压之间存在弱正相关,但与基础泪液渗透压无关。

结论

基础泪液的渗透压与反射性泪液的渗透压没有差异。泪液分泌量与反射性泪液渗透压之间存在弱正相关。手持渗透压计测量的泪液渗透压与泪液蕨类样形态之间未检测到相关性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验