To evaluate the efficacy and safety of injecting increasing volumes into the extravascular spaces of the choroid (EVSC) in rabbit eyes in vivo using a blunt adjustable depth injector.
Indocyanine green (ICG) was injected in the superior-temporal quadrant, 2 mm posterior to the limbus at increasing volumes (0.1-0.3 ml) into the EVSC of New Zealand rabbit eyes in vivo. Intraocular pressure (IOP) measurements, spectral domain optical coherence tomography (SD-OCT), fundus imaging and histology analysis were performed to assess the safety and efficacy of the injection.
Volumes up to 0.3 ml were administered consistently. ICG injection was successfully monitored in vivo using infrared fundus imaging and SD-OCT. ICG was detected across the EVSC compartment, reaching the retinal pigment epithelium, optic nerve head and visual streak. Injection of 0.3 ml yielded maximal dye distribution with a coverage area of 61.8% ± 6.7% (mean ± standard error, SE) of the posterior segment. Maximal IOP elevation was recorded 5 min following injection of 0.2 and 0.3 ml ICG (+ 20.0 mmHg, + 19.4 mmHg, respectively). Twenty minutes post-injection, the IOP was < 15 mmHg in all injection volumes. No retinal detachment or hemorrhages were detected in any of the injected eyes.
This study demonstrates consistent and safe delivery of large volumes within the EVSC using a blunt adjustable depth injector that distributes the dye over 60% of the retinal surface. This injection system may offer a minimally invasive and easy way to deliver large volumes of pharmaceuticals into the posterior segment.
评估使用钝性可调深度注射器向兔眼脉络膜(EVSC)的血管外空间(EVSC)中注入递增体积的疗效和安全性。
将吲哚菁绿(ICG)以递增体积(0.1-0.3ml)注入活体新西兰兔眼的上颞象限,距角膜缘后 2mm 处。通过眼压(IOP)测量、频域光学相干断层扫描(SD-OCT)、眼底成像和组织学分析来评估注射的安全性和疗效。
可一致给予高达 0.3ml 的体积。使用红外眼底成像和 SD-OCT 成功监测了 ICG 的体内注射。ICG 在 EVSC 隔室中被检测到,到达视网膜色素上皮、视神经头和视觉纹。注射 0.3ml 可获得最大的染料分布,后节覆盖率为 61.8%±6.7%(平均值±标准误差,SE)。注射 0.2 和 0.3ml ICG 后 5 分钟记录到最大眼压升高(分别为+20.0mmHg,+19.4mmHg)。注射后 20 分钟,所有注射体积的眼压均<15mmHg。在所有注射眼均未发现视网膜脱离或出血。
本研究使用钝性可调深度注射器证明了在 EVSC 中一致且安全地输送大体积药物,该注射器可将染料分布在超过 60%的视网膜表面。这种注射系统可能为向眼后节输送大体积药物提供一种微创、简便的方法。