Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors.

机构信息

Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland; Department of Clinical Research, University of Basel, Basel, Switzerland; Department of Biomedical Engineering, University of Basel, Basel, Switzerland.

Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland; Department of Clinical Research, University of Basel, Basel, Switzerland; Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Department of Spine Surgery, University Hospital Basel, Basel, Switzerland.

出版信息

Gait Posture. 2020 Sep;81:49-55. doi: 10.1016/j.gaitpost.2020.07.004. Epub 2020 Jul 6.

Abstract

BACKGROUND

The popularity of inertial sensors in gait analysis is steadily rising. To date, an application of a wearable inertial sensor system for assessing gait in hip osteoarthritis (OA) has not been reported.

RESEARCH QUESTION

Can the known kinematic differences between patients with hip OA and asymptomatic control subjects be measured using the inertial sensor system RehaGait®?

METHODS

The patients group consisted of 22 patients with unilateral hip OA scheduled for total hip replacement. Forty-five age matched healthy control subjects served as control group. All subjects walked for a distance of 20 m at their self-selected speed. Spatiotemporal parameters and sagittal kinematics at the hip, knee, and ankle including range of motion (ROM) were measured using the RehaGait® system.

RESULTS

Patients with hip OA walked at a slower walking speed (-0.18 m/s, P < 0.001) and with shorter stride length (-0.16 m, P < 0.001), smaller hip ROM during stance (-11.6°, P < 0.001) and swing (-11.3°, P < 0.001) and smaller knee ROM during terminal stance and swing (-9.0° and-11.5°, P < 0.001). Patients had a smaller hip ROM during stance and swing and smaller knee ROM during terminal stance and swing in the affected compared to the unaffected side (P < 0.001).

SIGNIFICANCE

The differences in spatiotemporal and kinematic gait parameters between patients with hip OA and age matched control subjects assessed using the inertial sensor system agree with those documented for camera-based systems. Hence, the RehaGait® system can measure gait kinematics characteristic for hip OA, and its use in daily clinical practice is feasible.

摘要

背景

惯性传感器在步态分析中的应用越来越普及。迄今为止,尚未有研究报告使用可穿戴惯性传感器系统评估髋关节炎(OA)患者的步态。

研究问题

能否使用惯性传感器系统 RehaGait® 测量髋 OA 患者与无症状对照者之间已知的运动学差异?

方法

患者组由 22 名计划接受全髋关节置换术的单侧髋 OA 患者组成。45 名年龄匹配的健康对照者作为对照组。所有受试者以自身选择的速度行走 20 米。使用 RehaGait®系统测量时空参数和髋、膝、踝矢状面运动学,包括运动范围(ROM)。

结果

髋 OA 患者的步行速度较慢(-0.18 m/s,P < 0.001),步长较短(-0.16 m,P < 0.001),站立期和摆动期髋关节 ROM 较小(-11.6°,P < 0.001)和摆动期(-11.3°,P < 0.001)以及终末期和摆动期膝关节 ROM 较小(-9.0°和-11.5°,P < 0.001)。与非患病侧相比,患者患病侧在站立期和摆动期髋关节 ROM 以及终末期和摆动期膝关节 ROM 较小(P < 0.001)。

意义

使用惯性传感器系统评估髋 OA 患者与年龄匹配的对照组之间的时空和运动学步态参数差异与基于摄像机系统记录的差异一致。因此,RehaGait®系统可以测量髋 OA 的运动学特征,其在日常临床实践中的应用是可行的。