• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Stress distribution in mandible induced by occlusal force in different horizontal mandibular positions].

作者信息

Ishida T, Soma K, Miura F

出版信息

Nihon Kyosei Shika Gakkai Zasshi. 1988 Dec;47(4):767-79.

PMID:3270673
Abstract

The objective of this study was to investigate the stress distribution in the mandible induced by occlusal forces in a various different horizontal mandibular positions identified as neutroclusion, distoclusion, mesioclusion, and laterally shifted occlusion. A three dimensional Finite Element Method (3D-FEM) was applied to an artificial model of a simulated mandible constructed as a homogeneous, isotropic and elastic body. This model was divided into 480 elements with 785 nodes. The right and left heads of the mandibular condyles and the occlusal surfaces of the posterior teeth of the model were restrained. These restraints acted against the loading of the masticatory forces which consisted of a pair of masseter, temporal, and also the lateral and medial pterygoid muscles. The stress distributions analyzed by 3D-FEM were graphically demonstrated on a three dimensional display system. The data obtained were summarized as follows: I. Neutroclusion (1) Tensile stress appeared along the anterior border of the ramus, and compressive stress appeared along the angular portion of the ramus. (2) Compressive and tensile stress appeared on the external and the internal surfaces of the anterior portion of the mandibular body. II. Distoclusion and mesioclusion (1) As the position of the mandible was moved distally, the absolute values of the stress tended to increase on the same areas which is the external and the internal surfaces of the anterior portion of the mandibular body. (2) Compressive stress which appeared on the occlusal surfaces of the posterior teeth was very great in distoclusion. At the same time, the stress that appeared on the heads of the mandibular condyle was also great in mesioclusion. III. Right laterally shifted occlusion (1) Tensile stress appeared along the left sides of both of the left and right rami, and compressive stress appeared along the right side of both of the left and right rami. (2) A great amount of stress appeared on the left occlusal surfaces of the posterior teeth and on the left portion of the mandibular body. From these results, it was determined probably that the mandibular morphogenesis was influenced by a series of stress factors which were induced by the forces of the masticatory muscles.

摘要

相似文献

1
[Stress distribution in mandible induced by occlusal force in different horizontal mandibular positions].
Nihon Kyosei Shika Gakkai Zasshi. 1988 Dec;47(4):767-79.
2
[Effect of change in occlusal contact areas of the mandibular second molar on temporomandibular joint stress distribution: a 3-dimensional finite element analysis].下颌第二磨牙咬合接触面积变化对颞下颌关节应力分布的影响:三维有限元分析
Zhonghua Kou Qiang Yi Xue Za Zhi. 2005 Jul;40(4):291-3.
3
[Stress distribution of mandible under different loading and biting condition].[不同加载和咬合条件下下颌骨的应力分布]
Sichuan Da Xue Xue Bao Yi Xue Ban. 2004 Jul;35(4):516-9.
4
Mandibular forces during simulated tooth clenching.模拟牙齿咬紧时的下颌力。
J Orofac Pain. 1994 Spring;8(2):178-89.
5
Finite element analysis of stresses in the maxillary and mandibular dental arches and TMJ articular discs during clenching into maximum intercuspation, anterior and unilateral posterior occlusion.在紧咬至最大牙尖交错位、前牙及单侧后牙咬合时,对上颌和下颌牙弓以及颞下颌关节关节盘内应力的有限元分析。
Stomatologija. 2007;9(4):121-8.
6
Three-dimensional finite element stress analysis of the dentate human mandible.人类有齿下颌骨的三维有限元应力分析
Am J Phys Anthropol. 1992 May;88(1):69-96. doi: 10.1002/ajpa.1330880107.
7
[Three-dimensional finite element stress analysis of supporting bone of mandibular posterior fixed bridge. Part III. Comparative analysis with stress of the cortical bone beneath different pontics of fixed bridge].
Hua Xi Kou Qiang Yi Xue Za Zhi. 2000 Feb;18(1):58-60.
8
Stress of tooth and PDL structure created by bite force.咬合力产生的牙齿和牙周膜结构应力。
Bull Tokyo Med Dent Univ. 1993 Dec;40(4):217-32.
9
Three-dimensional finite element analysis of mechanical stress in symphyseal fractured human mandible reduced with miniplates during mastication.咀嚼过程中使用微型钢板固定的耻骨联合骨折人类下颌骨机械应力的三维有限元分析
J Oral Maxillofac Surg. 2010 Jul;68(7):1585-92. doi: 10.1016/j.joms.2009.07.084.
10
[Studies on stress distribution under simulated muscles on dry skull].[干燥颅骨上模拟肌肉下应力分布的研究]
Nichidai Koko Kagaku. 1989 Sep;15(3):258-75.

引用本文的文献

1
The effect of fixation plate use on bone healing during the reconstruction of mandibular defects.在下颌骨缺损重建过程中使用固定钢板对骨愈合的影响。
J Korean Assoc Oral Maxillofac Surg. 2019 Oct;45(5):276-284. doi: 10.5125/jkaoms.2019.45.5.276. Epub 2019 Oct 30.