Abstract

The purpose of the present study was to determine the diagnostic accuracy of vaginal urea and creatinine levels in the detection of premature rupture of membrane (PROM). The Cochrane (central), EMBASE, PubMed, Scopus, and Web of Science were searched for studies published from the inception of the databases up to January 2020. We included published observational full-text articles. The mean differences (MD) and 95% confidence intervals (95% CI) were calculated. The significance level was set as 0.05. Eleven studies (n = 1324) were considered for meta-analysis. Using the bivariate model, the summary estimate of sensitivity and specificity for urea was 0.96 (95% CI: 0.86, 0.98) and 0.93 (95% CI: 0.83, 0.97), respectively. The summary estimate of sensitivity and specificity for creatinine was 0.98 (95% CI: 0.92, 0.99) and 0.97 (95% CI: 0.89, 0.99), respectively. The overall mean of urea and creatinine in the case group was significantly higher than that in the control group (MD = 12.63, 95%, CI [12.01, 13.25]) and (MD = 0.31, 95%, CI [0.29, 0.32]), respectively. The results of this systematic review showed that the mean of urea and creatinine in the case group was significantly higher than that in the control group and the sensitivity and specificity of creatinine is higher than urea in the diagnosis of PROM.

摘要

本研究旨在确定阴道尿素和肌酐水平在胎膜早破(PROM)检测中的诊断准确性。对 Cochrane(中央)、EMBASE、PubMed、Scopus 和 Web of Science 进行了检索,检索了从数据库建立到 2020 年 1 月发表的研究。纳入了已发表的观察性全文文章。计算了均值差异(MD)和 95%置信区间(95%CI)。显著性水平设定为 0.05。有 11 项研究(n=1324)进行了荟萃分析。使用双变量模型,尿素的汇总估计敏感性和特异性分别为 0.96(95%CI:0.86,0.98)和 0.93(95%CI:0.83,0.97)。肌酐的汇总估计敏感性和特异性分别为 0.98(95%CI:0.92,0.99)和 0.97(95%CI:0.89,0.99)。病例组尿素和肌酐的总体平均值明显高于对照组(MD=12.63,95%CI[12.01,13.25])和(MD=0.31,95%CI[0.29,0.32])。本系统评价的结果表明,病例组尿素和肌酐的平均值明显高于对照组,且肌酐的敏感性和特异性均高于尿素,可用于诊断 PROM。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验