Suppr超能文献

用于 OECD 测试指南 439 的体外皮肤刺激试验的同型物验证研究,使用 KeraSkin™ 人体重建表皮模型。

Me-too validation study for in vitro skin irritation test with a reconstructed human epidermis model, KeraSkin™ for OECD test guideline 439.

机构信息

College of Pharmacy, Ewha Womans University, Seoul, Republic of Korea.

Biosolution Co, Seoul, Republic of Korea.

出版信息

Regul Toxicol Pharmacol. 2020 Nov;117:104725. doi: 10.1016/j.yrtph.2020.104725. Epub 2020 Aug 5.

Abstract

We conducted a me-too validation study to confirm the reproducibility, reliability, and predictive capacity of KeraSkin™ skin irritation test (SIT) as a me-too method of OECD TG 439. With 20 reference chemicals, within-laboratory reproducibility (WLR) of KeraSkin™ SIT in the decision of irritant or non-irritant was 100%, 100%, and 95% while between-laboratory reproducibility (BLR) was 100%, which met the criteria of performance standard (PS, WLR≥90%, BLR≥80%). WLR and BLR were further confirmed with intra-class correlation (ICC, coefficients >0.950). WLR and BLR in raw data (viability) were also shown with a scatter plot and Bland-Altman plot. Comparison with existing VRMs with Bland-Altman plot, ICC and kappa statistics confirmed the compatibility of KeraSkin™ SIT with OECD TG 439. The predictive capacity of KeraSkin™ SIT was estimated with 20 reference chemicals (the sensitivity of 98.9%, the specificity of 70%, and the accuracy of 84.4%) and additional 46 chemicals (for 66 chemicals [20 + 46 chemicals, the sensitivity, specificity and accuracy: 95.2%, 82.2% and 86.4%]). The receiver operating characteristic (ROC) analysis suggested a potential improvement of the predictive capacity, especially sensitivity, when changing cut-off (50% → 60-75%). Collectively, the me-too validation study demonstrated that KeraSkin™ SIT can be a new me-too method for OECD TG 439.

摘要

我们进行了一项类似物验证研究,以确认 KeraSkin™皮肤刺激试验(SIT)作为 OECD TG 439 的类似物方法的重现性、可靠性和预测能力。使用 20 种参考化学品,KeraSkin™ SIT 在判断刺激物或非刺激物方面的实验室内重现性(WLR)为 100%、100%和 95%,而实验室间重现性(BLR)为 100%,符合性能标准(WLR≥90%,BLR≥80%)的要求。WLR 和 BLR 还通过组内相关系数(ICC,系数>0.950)得到进一步确认。WLR 和 BLR 在原始数据(存活率)中也通过散点图和 Bland-Altman 图显示。与现有的 VRMs 进行 Bland-Altman 图、ICC 和 Kappa 统计分析比较,证实了 KeraSkin™ SIT 与 OECD TG 439 的兼容性。使用 20 种参考化学品(敏感性 98.9%,特异性 70%,准确性 84.4%)和另外 46 种化学品(66 种化学品[20+46 种化学品],敏感性、特异性和准确性:95.2%、82.2%和 86.4%)评估了 KeraSkin™ SIT 的预测能力。接收者操作特征(ROC)分析表明,当改变截断值(50%→60-75%)时,预测能力,特别是敏感性,可能会有所提高。总的来说,这项类似物验证研究表明,KeraSkin™ SIT 可以成为 OECD TG 439 的一种新的类似物方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验