Abstract

A large or persistent urethrovesical anastomotic leakage after a laparoscopic or robot-assisted laparoscopic radical prostatectomy (RALRP) although infrequent can be a difficult complication to treat. We describe a simple technique to facilitate resolution of a urethrovesical anastomotic leak by exchanging the in-place bladder Foley catheter for a pigtail drainage catheter. Between 2014 and 2019, we had three patients who had a large/persistent urine leak after a radical prostatectomy (one laparoscopic and two robot assisted). All three patients had a wide bladder neck requiring bladder neck reconstruction with ureteral orifices close to the anastomosis. The bladder Foley catheter was exchanged to a pigtail Cope loop catheter™ (14F) or an Origin™ self-retaining drainage catheter (16F) under flexible cystoscopic guidance over a guidewire. Placement of a Cope loop bladder catheter stopped anastomotic leakage expeditiously with no need for further intervention. At minimum 3 months follow-up none had bladder neck stricture with 0-1 pad urinary incontinence. Drainage of the bladder through the use of a loop pigtail nephrostomy catheter can be useful in rapidly resolving a large persistent urethrovesical anastomotic leak.

摘要

腹腔镜或机器人辅助腹腔镜根治性前列腺切除术后出现大的或持续性尿道膀胱吻合口漏,虽然不常见,但却是一种难以处理的并发症。我们描述一种简单的技术,通过将膀胱内留置的Foley导尿管更换为猪尾引流导管,以促进尿道膀胱吻合口漏的解决。在2014年至2019年期间,我们有3例患者在根治性前列腺切除术后出现大的/持续性尿漏(1例腹腔镜手术,2例机器人辅助手术)。所有3例患者的膀胱颈均较宽,需要进行膀胱颈重建,输尿管口靠近吻合口。在可弯曲膀胱镜引导下,通过导丝将膀胱Foley导尿管更换为猪尾Cope环导管™(14F)或Origin™自固定引流导管(16F)。放置Cope环膀胱导管可迅速停止吻合口漏,无需进一步干预。至少3个月的随访显示,无一例出现膀胱颈狭窄,尿失禁情况为0 - 1片尿垫。通过使用环猪尾肾造瘘导管进行膀胱引流,有助于迅速解决大的持续性尿道膀胱吻合口漏。

相似文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验