Suppr超能文献

牙本质湿度不影响后牙修复体的术后敏感性:一项双盲随机临床试验。

Dentin moisture does not influence postoperative sensitivity in posterior restorations: A double-blind randomized clinical trial.

作者信息

Castro Andrea S, Maran Bianca M, Gutiérrez Mario F, Martini Eveline C, Dreweck Fabiana Ds, Mendez-Bauer Luján, Reis Alessandra, Loguercio Alessandro D

机构信息

Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, PR, Brazil.

Postgraduate Program in Dentistry, School of Dentistry, University of North Paraná, Londrina, Paraná, Brazil.

出版信息

Am J Dent. 2020 Aug;33(4):206-212.

Abstract

PURPOSE

This double-blind, randomized clinical trial evaluated the influence of dentin moisture on postoperative sensitivity (POS) in posterior restorations using a simplified etch-and-rinse adhesive, until 12 months of clinical service.

METHODS

90 restorations were inserted in 45 patients to treat carious lesions or to replace existing posterior restorations with a depth ≥ 3 mm. After cavity preparation, the simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied on dry or wet dentin followed by a bulk-fill resin composite (Filtek Bulk Fill) under rubber dam isolation. The patient's spontaneous and stimulated POS was evaluated at baseline and after 7 days, 6 months, and 12 months of clinical evaluation. The secondary parameters (marginal discoloration, marginal adaptation, fracture and recurrence of caries) were evaluated by World Dental Federation (FDI) criteria after 7 days, 6 and 12 months of clinical evaluation.

RESULTS

No significant spontaneous and stimulated POS was observed when dry and wet dentin were compared (P> 0.05). A significant and higher risk of spontaneous POS (18.6%; 95% CI 9.7 to 32.6) occurred up to 48 hours after restoration placement for both groups when compared to all evaluation times (P< 0.03). However, the intensity of POS was mild at up to 48 hours with a difference between the dry and wet dentin groups (P> 0.79). When secondary parameters were evaluated, no significant difference between the groups were observed (P> 0.05).

CLINICAL SIGNIFICANCE

The moisture level of the dentin substrate in posterior restorations does not influence POS in bulk-fill resin composite posterior restorations when associated with an etch-and-rinse ethanol-based adhesive system.

摘要

目的

本双盲随机临床试验评估了使用简化酸蚀冲洗粘结剂的后牙修复体中牙本质湿度对术后敏感(POS)的影响,临床观察期为12个月。

方法

45例患者共植入90颗修复体,用于治疗龋损或替换深度≥3mm的现有后牙修复体。窝洞预备后,在干燥或湿润的牙本质上应用简化酸蚀冲洗粘结剂(Adper Single Bond 2),然后在橡皮障隔离下填充大颗粒复合树脂(Filtek Bulk Fill)。在基线以及临床评估7天、6个月和12个月后评估患者的自发和激发性POS。临床评估7天、6个月和12个月后,根据世界牙科联盟(FDI)标准评估次要参数(边缘变色、边缘适应性、骨折和龋病复发)。

结果

比较干燥和湿润牙本质时,未观察到显著的自发和激发性POS(P>0.05)。与所有评估时间相比,两组在修复体放置后48小时内发生自发POS的风险显著更高(18.6%;95%CI 9.7至32.6)(P<0.03)。然而,在48小时内POS强度较轻,干燥和湿润牙本质组之间存在差异(P>0.79)。评估次要参数时,两组之间未观察到显著差异(P>0.05)。

临床意义

当与基于乙醇的酸蚀冲洗粘结系统联合使用时,后牙修复体中牙本质基质的湿度水平不会影响大颗粒复合树脂后牙修复体的POS。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验