酶联免疫吸附法与免疫荧光法在HIV感染血清学诊断中的比较。

Comparison between enzyme-linked immunosorbent and I.F. assays in the serological diagnosis of HIV infections.

作者信息

Borghi V, De Palma M, Vecchi M, Pellegrino F, Mongiardo N, Cocchi I, De Rienzo B, Squadrini F

机构信息

Department of Infectious Diseases, University of Modena, Italy.

出版信息

Microbiologica. 1988 Jan;11(1):81-4.

PMID:3280951
Abstract

A rapid, sensitive indirect immunofluorescence assay based on the use of acetone-fixed virus producing MOLT T4/LAV cells was adapted for the detection of anti-HIV antibodies. At the same time, 1486 serum samples, collected by the AIDS Surveillance and Study Centre of Modena, were tested by ELISA and IFA: the percentage of agreement of both assays was of 99.66%. Such datum suggested that IFA could be used as a serological assay for screening and confirmatory purposes.