Yoshida T, Matsui T, Kobayashi S, Harada S, Kurimura T, Hinuma Y, Yamamoto N
Jpn J Cancer Res. 1986 Dec;77(12):1211-3.
A new serological test, the gelatin particle agglutination (PA) test, was developed for the detection of antibody to human immunodeficiency virus (HIV). The sensitivity of the PA test was the same as that of enzyme-linked immunosorbent assay (ELISA) among 761 US and Japanese sera tested. However, false-positive cases were found in 1.2% of all sera in ELISA but in 0% in the PA test (P less than 0.05). There was 100% agreement of seropositivity between PA and a confirmatory indirect immunofluorescence (IF) test. In addition, the agglutination test was reproducible. Thus, the test should be useful for the mass screening of anti-HIV antibody in blood donors.
一种新的血清学检测方法——明胶颗粒凝集(PA)试验,被开发用于检测人类免疫缺陷病毒(HIV)抗体。在对761份美国和日本血清进行检测时,PA试验的灵敏度与酶联免疫吸附测定(ELISA)相同。然而,ELISA检测的所有血清中有1.2%出现假阳性病例,而PA试验中假阳性率为0%(P<0.05)。PA试验与确证性间接免疫荧光(IF)试验之间的血清阳性结果完全一致。此外,凝集试验具有可重复性。因此,该试验对于献血者抗HIV抗体的大规模筛查应是有用的。