Brook Itzhak
Department of Pediatrics and Medicine, Georgetown University School of Medicine, Washington, DC, USA.
J Med Ultrasound. 2019 Dec 26;28(2):114-116. doi: 10.4103/JMU.JMU_77_19. eCollection 2020 Apr-Jun.
Paroxysmal hypertension (PH) can be associated with the carotid artery baroreceptors' failure due to past exposure to radiation treatment. This report presents a patient who experienced repeated PH episodes due to the direct massage of the carotid artery during Doppler ultrasound of the neck. The radiation damage to the carotid artery baroreceptors might have increased their hypersensitivity to the mechanical and ultrasonic stimulation during the diagnostic test, leading to the hypertensive episodes. Patients who had received radiation therapy for head-and-neck cancer and require Doppler ultrasound of the carotid artery should be monitored for PH by recording their blood pressure prior and after the test.
阵发性高血压(PH)可能与既往接受放射治疗导致的颈动脉压力感受器功能衰竭有关。本报告介绍了一名患者,其在颈部多普勒超声检查期间因颈动脉直接按摩而经历反复的PH发作。颈动脉压力感受器的辐射损伤可能增加了它们在诊断测试期间对机械和超声刺激的超敏反应,从而导致高血压发作。对头颈部癌接受过放射治疗且需要进行颈动脉多普勒超声检查的患者,应在检查前后记录血压,以监测是否发生PH。