Suppr超能文献

锥形束 CT 三维重建灰度值阈值对光学扫描图像匹配精度的影响。

Impacts of Thresholds of Gray Value for Cone-Beam Computed Tomography 3D Reconstruction on the Accuracy of Image Matching with Optical Scan.

机构信息

Department of Prosthodontics, School of Dentistry, Institute for Translational Research in Dentistry, Kyungpook National University, Daegu 41940, Korea.

Department of Radiology, Nowon Eulji Medical Center, Eulji University, Seoul 01830, Korea.

出版信息

Int J Environ Res Public Health. 2020 Sep 1;17(17):6375. doi: 10.3390/ijerph17176375.

Abstract

In cone-beam computed tomography (CBCT), the minimum threshold of the gray value of segmentation is set to convert the CBCT images to the 3D mesh reconstruction model. This study aimed to assess the accuracy of image registration of optical scans to 3D CBCT reconstructions created by different thresholds of grey values of segmentation in partial edentulous jaw conditions. CBCT of a dentate jaw was reconstructed to 3D mesh models using three different thresholds of gray value (-500, 500, and 1500), and three partially edentulous models with different numbers of remaining teeth (4, 8, and 12) were made from each 3D reconstruction model. To merge CBCT and optical scan data, optical scan images were registered to respective 3D reconstruction CBCT images using a point-based best-fit algorithm. The accuracy of image registration was assessed by measuring the positional deviation between the matched 3D images. The Kruskal-Wallis test and a post hoc Mann-Whitney U test with Bonferroni correction were used to compare the results between groups (α = 0.05). The correlations between the experimental factors were calculated using the two-way analysis of variance test. The positional deviations were lowest with the threshold of 500, followed by the threshold of 1500, and then -500. A significant interaction was found between the threshold of gray values and the number of remaining teeth on the registration accuracy. The most significant deviation was observed in the arch model with four teeth reconstructed with a gray-value threshold of -500. The threshold for the gray value of CBCT segmentation affects the accuracy of image registration of optical scans to the 3D reconstruction model of CBCT. The appropriate gray value that can visualize the anatomical structure should be set, especially when few teeth remain in the dental arch.

摘要

在锥形束 CT(CBCT)中,分割的灰度值最小阈值被设置为将 CBCT 图像转换为 3D 网格重建模型。本研究旨在评估在部分无牙颌条件下,使用不同分割灰度值阈值创建的光学扫描与 3D CBCT 重建图像的配准精度。使用三种不同的灰度值阈值(-500、500 和 1500)对有牙颌的 CBCT 进行 3D 网格重建,并从每个 3D 重建模型中制作三个具有不同剩余牙齿数量(4、8 和 12)的部分无牙模型。为了合并 CBCT 和光学扫描数据,使用基于点的最佳拟合算法将光学扫描图像注册到各自的 3D 重建 CBCT 图像。通过测量匹配的 3D 图像之间的位置偏差来评估图像配准的准确性。使用 Kruskal-Wallis 检验和事后 Mann-Whitney U 检验(Bonferroni 校正)比较组间结果(α=0.05)。使用双向方差分析检验计算实验因素之间的相关性。阈值为 500 时位置偏差最低,其次是阈值为 1500,然后是阈值为-500。在配准精度方面,灰度值阈值和剩余牙齿数量之间存在显著的交互作用。在重建灰度值阈值为-500 的情况下,牙齿数量为 4 的牙弓模型观察到最大偏差。CBCT 分割的灰度值阈值会影响光学扫描与 CBCT 3D 重建模型图像配准的准确性。应设置适当的灰度值,以可视化解剖结构,尤其是当牙弓中剩余牙齿较少时。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验