• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?

作者信息

Kandemir Göksu, Smith Simon, Chen Jinju, Joyce Thomas J

机构信息

School of Engineering, Newcastle University, Newcastle Upon Tyne, UK.

School of Engineering, Newcastle University, Newcastle Upon Tyne, UK.

出版信息

J Mech Behav Biomed Mater. 2020 Dec;112:104067. doi: 10.1016/j.jmbbm.2020.104067. Epub 2020 Aug 28.

DOI:10.1016/j.jmbbm.2020.104067
PMID:32905920
Abstract

Using a 50-station pin-on-disc (SuperCTPOD) machine, the influence of lubricant viscosity on the wear of vitamin E blended crosslinked polyethylene was investigated. Five different test lubricants were prepared by mixing different concentrations of carboxymethyl cellulose powder with deionised water. The viscosity range of the lubricants was 0.002-0.155 Pa, a range that represents the viscosities of diseased and healthy synovial fluids. Five groups of pins (10 pins in each group) were articulated against cobalt chromium discs. Wear was measured in terms of weight loss from each pin and disc for every group. Every 500,000 cycles the experiment was stopped to take gravimetric measurements along with roughness measurements of the articulating surfaces. The test discs did not show a significant change in weight after 2.5 million cycles of testing (p > 0.05). For the pins, the group tested with the lowest viscosity (0.002 Pa) produced the highest wear rate, namely 0.931 mg/million cycles, and the wear rates of the other groups were 0.074, 0.027, 0.034 and 0.021 mg/million cycles respectively. The wear rates calculated for the five groups were all lower than the wear rates recorded for ultrahigh molecular weight polyethylene and not significantly different to crosslinked polyethylene. In addition, apart from group 1 pins (tested with the lowest lubricant viscosity (0.002 Pa)), the machining marks on the other pins were still present after 2.5 million cycles of testing, indicating low wear.

摘要

相似文献

1
How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?
J Mech Behav Biomed Mater. 2020 Dec;112:104067. doi: 10.1016/j.jmbbm.2020.104067. Epub 2020 Aug 28.
2
Wear behaviour of CFR PEEK articulated against CoCr under varying contact stresses: Low wear of CFR PEEK negated by wear of the CoCr counterface.不同接触应力下 CFR PEEK 关节对 CoCr 的磨损行为:CFR PEEK 的低磨损被 CoCr 对磨面的磨损所抵消。
J Mech Behav Biomed Mater. 2019 Sep;97:117-125. doi: 10.1016/j.jmbbm.2019.05.022. Epub 2019 May 15.
3
Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device.采用多向运动销盘装置研究配对表面粗糙度对传统和交联超高分子量聚乙烯磨损的影响。
J Biomed Mater Res. 2001 Dec 15;57(4):506-12. doi: 10.1002/1097-4636(20011215)57:4<506::aid-jbm1196>3.0.co;2-h.
4
Does cyclic stress and accelerated ageing influence the wear behavior of highly crosslinked polyethylene?循环应力和加速老化会影响高度交联聚乙烯的磨损行为吗?
J Mech Behav Biomed Mater. 2016 Jun;59:418-429. doi: 10.1016/j.jmbbm.2016.02.029. Epub 2016 Mar 2.
5
In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials.用于骨科生物材料磨损测试的替代润滑剂的体外测试。
Proc Inst Mech Eng H. 2013 Jun;227(6):693-703. doi: 10.1177/0954411913481549. Epub 2013 Apr 9.
6
The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.在多向销盘试验机上,聚醚醚酮对交联聚乙烯轴承的生物摩擦学性能与传统轴承相当。
Clin Orthop Relat Res. 2016 Nov;474(11):2384-2393. doi: 10.1007/s11999-016-4989-7.
7
The influence of contact stress on the wear of cross-linked polyethylene.接触应力对交联聚乙烯磨损的影响。
Proc Inst Mech Eng H. 2018 Oct;232(10):1008-1016. doi: 10.1177/0954411918796047. Epub 2018 Aug 23.
8
In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE.标准型、交联型和维生素 E 共混型超高分子量聚乙烯的体外磨损性能。
J Biomed Mater Res A. 2012 Mar;100(3):554-60. doi: 10.1002/jbm.a.33297. Epub 2011 Dec 12.
9
The biochemical characteristics of wear testing lubricants affect polyethylene wear in orthopaedic pin-on-disc testing.磨损测试润滑剂的生化特性会影响骨科销盘测试中的聚乙烯磨损。
Proc Inst Mech Eng H. 2015 Jan;229(1):77-90. doi: 10.1177/0954411914567930.
10
Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant.使用具有临床相关性的透明质酸模拟润滑剂时,全膝关节置换术中超高分子量聚乙烯磨损增加。
Proc Inst Mech Eng H. 2006 Jul;220(5):609-23. doi: 10.1243/09544119JEIM30.