Zhao C, Yang J, Liu Y, Gao M, Chen P, Zheng J, Zhao S
Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, China.
J Laryngol Otol. 2020 Sep 16:1-8. doi: 10.1017/S0022215120001899.
This study aimed to investigate the benefit of Bonebridge devices in patients with single-sided deafness.
Five patients with single-sided deafness who were implanted with Bonebridge devices were recruited in a single-centre study. Participants' speech perception and horizontal sound localisation abilities were assessed at 6 and 12 months post-operatively. Speech intelligibility in noisy environments was measured in three different testing conditions (speech and noise presented from the front, speech and noise presented from the front and contralateral (normal ear) side separately, and speech presented from the ipsilateral (implanted Bonebridge) side and noise from the contralateral side). Sound localisation was evaluated in Bonebridge-aided and Bonebridge-unaided conditions at different stimuli levels (65, 70 and 75 dB SPL).
All participants showed a better capacity for speech intelligibility in quiet environments with the Bonebridge device. The speech recognition threshold with the Bonebridge device was significantly decreased at both short- and long-term follow up in the speech presented from the ipsilateral (implanted Bonebridge) side and noise from the contralateral side condition (p < 0.05). Additionally, participants maintained similar levels of sound localisation between the Bonebridge-aided and unaided conditions (p > 0.05). However, the accuracy of localisation showed some improvement at 70 dB SPL and 75 dB SPL post-operatively.
The Bonebridge device provides the benefit of improved speech perception performance in patients with single-sided deafness. Sound localisation abilities were neither improved nor worsened with Bonebridge implantation at the follow-up assessments.
本研究旨在调查骨桥设备对单侧耳聋患者的益处。
在一项单中心研究中招募了5名单侧耳聋并植入骨桥设备的患者。在术后6个月和12个月评估参与者的言语感知和水平声音定位能力。在三种不同的测试条件下测量嘈杂环境中的言语可懂度(语音和噪声从正面呈现、语音和噪声分别从正面和对侧(正常耳)侧呈现、语音从同侧(植入骨桥的一侧)呈现且噪声从对侧呈现)。在不同刺激水平(65、70和75 dB SPL)下,在骨桥辅助和无骨桥辅助条件下评估声音定位。
所有参与者在使用骨桥设备时在安静环境中的言语可懂度能力均有所提高。在同侧(植入骨桥的一侧)呈现语音且对侧呈现噪声的条件下,短期和长期随访时骨桥设备的言语识别阈值均显著降低(p < 0.05)。此外,参与者在骨桥辅助和无辅助条件下的声音定位水平相似(p > 0.05)。然而,术后在70 dB SPL和75 dB SPL时定位准确性有一定提高。
骨桥设备为单侧耳聋患者提供了改善言语感知性能的益处。在随访评估中,骨桥植入并未改善也未恶化声音定位能力。