Suppr超能文献

圆锥角膜患者穿透性角膜移植术与深前板层角膜移植术的角膜密度测量比较

Comparison of Corneal Densitometry Between Penetrating Keratoplasty and Deep Anterior Lamellar Keratoplasty in Keratoconus Patients.

作者信息

Karaca Emine Esra, Özek Dilay, Evren Kemer Özlem

机构信息

From the Ankara City Hospital, Department of Ophthalmology, Ankara, Turkey.

出版信息

Exp Clin Transplant. 2020 Sep 17. doi: 10.6002/ect.2020.0072.

Abstract

OBJECTIVES

Our aim was to compare corneal densitometry values in keratoconic eyes undergoing deep anterior lamellar keratoplasty with the "big bubble" and manual lamellar dissection techniques, as well as penetrating keratoplasty.

MATERIALS AND METHODS

This retrospective study evaluated the postoperative outcomes of 31 eyes treated with big bubble-deep anterior lamellar keratoplasty, 23 eyes with manual lamellar dissectiondeep anterior lamellar keratoplasty, and 37 eyes with penetrating keratoplasty. Corneal densitometry, best corrected visual acuity, and other corneal tomographic parameters were recorded at 1, 6, 12, and 24 months postoperatively. The groups were compared with respect to the outcomes.

RESULTS

There were no significant differences between the groups with respect to the anterior, central, and total corneal densitometry values at 0 to 2 mm and 2 to 6 mm. At 1 month postoperatively, the densitometric value in the posterior corneal layer of the 0- to 2-mm and 2- and 6-mm corneal zones was higher in the manual lamellar dissection-deep anterior lamellar keratoplasty group than in the big bubble-deep anterior lamellar keratoplasty and penetrating keratoplasty groups (P = .001). At 6, 12, and 24 months, the manual lamellar dissectiondeep anterior lamellar keratoplasty and penetrating keratoplasty groups had similar values in both zones in the posterior layer. The difference between manual lamellar dissection-deep anterior lamellar keratoplasty and big bubble-deep anterior lamellar keratoplasty in both zones in the posterior layer was statistically significant at 6, 12, and 24 months postoperatively (P < .05). The best corrected visual acuity of big bubble-deep anterior lamellar kerat oplasty and penetrating keratoplasty groups was better than that of the manual lamellar dissection-deep anterior lamellar keratoplasty group (P = .047).

CONCLUSIONS

Corneal densitometry values may vary depending on the type of keratoplasty used in keratoconus patients. Higher densitometry values may affect visual quality in keratoplasty patients by decreasing or filtering the light that reaches the retina.

摘要

目的

我们的目的是比较采用“大泡”和手动板层分离技术的深层前板层角膜移植术以及穿透性角膜移植术治疗圆锥角膜患者的角膜密度测量值。

材料与方法

这项回顾性研究评估了31只接受大泡深层前板层角膜移植术、23只接受手动板层分离深层前板层角膜移植术以及37只接受穿透性角膜移植术治疗的眼睛的术后结果。在术后1、6、12和24个月记录角膜密度测量值、最佳矫正视力及其他角膜断层扫描参数。对各治疗组的结果进行比较。

结果

在0至2毫米和2至6毫米处,各治疗组在前部、中央和全角膜密度测量值方面无显著差异。术后1个月时,手动板层分离深层前板层角膜移植术组0至2毫米和2至6毫米角膜区域的后角膜层密度测量值高于大泡深层前板层角膜移植术组和穿透性角膜移植术组(P = 0.001)。在术后6、12和24个月时,手动板层分离深层前板层角膜移植术组和穿透性角膜移植术组在后角膜层的这两个区域具有相似的值。术后6、12和24个月时,手动板层分离深层前板层角膜移植术组和大泡深层前板层角膜移植术组在后角膜层的这两个区域的差异具有统计学意义(P < 0.05)。大泡深层前板层角膜移植术组和穿透性角膜移植术组的最佳矫正视力优于手动板层分离深层前板层角膜移植术组(P = 0.047)。

结论

圆锥角膜患者角膜密度测量值可能因所采用的角膜移植术类型而异。较高的密度测量值可能通过减少或过滤到达视网膜的光线来影响角膜移植患者的视觉质量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验