Alzahrani Khaled, Dardin Syarifah-Faiza, Carley Fiona, Brahma Arun, Morley Debbie, Hillarby M Chantal
Division of Pharmacy and Optometry, School of Health Sciences, University of Manchester, Manchester, UK.
Manchester Royal Eye Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK.
Clin Ophthalmol. 2018 Mar 23;12:577-585. doi: 10.2147/OPTH.S157286. eCollection 2018.
To compare the corneal clarity measurement between penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK) in patients with keratoconus, using densitometry software for the Oculus Pentacam.
A retrospective comparative study was carried out at Manchester Royal Eye Hospital. Data were collected 12-18 months after corneal transplantation for keratoconus, including postoperative corneal densitometry, best corrected visual acuity (BCVA), central corneal thickness (CCT), and other relevant clinical details.
Analysis of 37 keratoconus eyes from 36 patients found there was a significantly higher corneal densitometry measurement after DALK than PK. This was predominantly in the posterior layer of the concentric zone 0-2 mm of the cornea (=0.0004). A significant correlation was found between postoperative BCVA and corneal densitometry in DALK groups at full thickness (=0.03). This correlation was seen in the central 0-2 mm (=0.03) and posterior 0-2 mm (=0.04) zones. In addition, within the DALK group, a correlation was found between central corneal thickness and densitometry at full thickness 2-6 mm (=0.007), central 0-2 (=0.04), central 2-6 mm (=0.01), and at posterior 2-6 mm (=0.01) zones.
This study showed that corneal densitometry measurement differs depending on the type of corneal transplantation used to treat keratoconus patients. Densitometry may have an important role to play in the final BCVA achieved by patients undergoing corneal transplantation for keratoconus. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the cornea status after the surgery.
使用Oculus Pentacam的密度测量软件,比较圆锥角膜患者穿透性角膜移植术(PK)和深前板层角膜移植术(DALK)后的角膜清晰度测量结果。
在曼彻斯特皇家眼科医院进行了一项回顾性对照研究。收集圆锥角膜患者角膜移植术后12 - 18个月的数据,包括术后角膜密度测量、最佳矫正视力(BCVA)、中央角膜厚度(CCT)以及其他相关临床细节。
对36例患者的37只圆锥角膜眼进行分析发现,DALK术后角膜密度测量值显著高于PK术后。这主要出现在角膜同心区0 - 2mm的后层(P = 0.0004)。在DALK组中,全层术后BCVA与角膜密度测量之间存在显著相关性(P = 0.03)。在中央0 - 2mm(P = 0.03)和后部0 - 2mm(P = 0.04)区域也可见这种相关性。此外,在DALK组内,全层2 - 6mm(P = 0.007)、中央0 - 2mm(P = 0.04)、中央2 - 6mm(P = 0.01)以及后部2 - 6mm(P = 0.01)区域的中央角膜厚度与密度测量之间存在相关性。
本研究表明,用于治疗圆锥角膜患者的角膜移植类型不同,角膜密度测量结果也不同。密度测量可能在圆锥角膜患者角膜移植术后最终达到的BCVA中发挥重要作用。对Oculus Pentacam图像的分析为监测术后角膜状态提供了客观评估。