INTRODUCTION AND OBJECTIVES

This report presents the findings of the 2019 Spanish Catheter Ablation Registry.

METHODS

Data collection was retrospective. A standardized questionnaire was filled by each of the participant centers.

RESULTS

Data sent by 102 centers were analyzed, with a total number of ablation procedures performed of 18 549 (the highest historically reported in this registry) for a mean of 181.9 ± 137.0 and a median of 144.5 procedures per center. The ablation targets most frequently treated were atrial fibrillation (n = 5164; 27.8%), cavotricuspid isthmus (n = 3925; 21.1%) and atrioventricular nodal reentrant tachycardia (n = 3768; 20.3%). A new peak is observed in the ablation of atrial fibrillation, increasing the distance from the other substrates. The overall success rate was again 91%. The rate of major complications was 1.9%, and the mortality rate was 0.03%. An electroanatomic mapping system was used in 44.5% of all procedures, with contact force-sensing irrigated catheters become the preferred for complex substrates, as atrial fibrillation (84.8%) or ventricular tachycardia (around 90%). 1.5% of the ablations were performed in pediatric patients.

CONCLUSIONS

The Spanish Catheter Ablation Registry enrolls systematically and uninterruptedly the ablation procedures performed in Spain, showing a progressive increasing in the number of ablations over the years with a high success rate and low percentages of complications.

摘要

引言与目标

本报告展示了2019年西班牙导管消融注册研究的结果。

方法

数据收集采用回顾性方式。每个参与中心填写一份标准化问卷。

结果

分析了102个中心发送的数据,共进行了18549例消融手术(该注册研究历史上报告的最高数量),每个中心平均进行181.9±137.0例,中位数为144.5例。最常治疗的消融靶点是心房颤动(n = 5164;27.8%)、腔静脉三尖瓣峡部(n = 3925;21.1%)和房室结折返性心动过速(n = 3768;20.3%)。观察到心房颤动消融出现新高峰,与其他消融靶点的差距增大。总体成功率再次为91%。主要并发症发生率为1.9%,死亡率为0.03%。44.5%的手术使用了电解剖标测系统,对于复杂靶点,如心房颤动(84.8%)或室性心动过速(约90%),带接触力感知的灌注射频导管成为首选。1.5%的消融手术在儿科患者中进行。

结论

西班牙导管消融注册研究系统且不间断地登记了西班牙进行的消融手术,显示出多年来消融手术数量逐渐增加,成功率高且并发症发生率低。