Suppr超能文献

髋关节骨关节炎患者行骨水泥非骨水泥假体翻修术治疗双极骨水泥半髋关节置换术后假体迁移:环套固定技术的中期疗效

Midterm results of revision total hip arthroplasty for migrated bipolar hemiarthroplasty in patients with hip osteoarthritis using cementless cup with the rim-fit technique.

机构信息

Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, 13143The University of Tokyo, Hongo, Bunkyo-ku, Tokyo, Japan.

Division of Science for Joint Reconstruction, Graduate School of Medicine, 13143The University of Tokyo, Hongo, Bunkyo-ku, Tokyo, Japan.

出版信息

J Orthop Surg (Hong Kong). 2020 Sep-Dec;28(3):2309499020954315. doi: 10.1177/2309499020954315.

Abstract

PURPOSE

The results of reamed bipolar hemiarthroplasty (BHA) in patients with hip osteoarthritis (OA) are reported to be unfavorable. Acetabular reaming for sufficient bony coverage caused bipolar head migration into the superomedial direction, and most patients required revision surgeries. Several methods are applicable to treat decreased bone stock. This study aimed to investigate the midterm results of revision surgeries using the cementless cup with the rim-fit technique.

METHODS

Between 1996 and 2014, acetabular revision surgeries using the cementless cup with the rim-fit technique were performed in 86 hips (74 patients). We evaluated radiographic outcomes, including positional change of the rotation center of the artificial femoral head, presence of implant loosening, and filling of the initial gap. We also evaluated clinical outcomes, including the Harris hip score (HHS), and postoperative complications.

RESULTS

The average positional changes from BHA to prerevision surgeries were 8.0 mm superiorly and 4.1 mm medially. The average changes from prerevision to postrevision surgeries were 3.7 mm inferiorly and 2.4 mm laterally. No implant loosening was found in all cases; the initial gap between the acetabular host bone and the acetabular cup was filled in 53 (93%) among 57 hips. The average HHS improved from 65.9 before revision surgeries to 83.8 in the latest follow-up. Dislocation and postoperative periprosthetic fracture occurred in two and five hips, respectively; no cases required rerevision surgeries.

CONCLUSION

There were favorable midterm results of the revision total hip arthroplasty for migrated BHA in patients with hip OA using cementless cup with the rim-fit technique.

摘要

目的

有研究报道,在患有髋关节骨关节炎(OA)的患者中,扩髓双极半髋关节置换术(BHA)的效果并不理想。为了获得充分的骨覆盖,髋臼扩孔会导致双极股骨头向内侧上方迁移,大多数患者需要接受翻修手术。有几种方法适用于治疗骨量减少的情况。本研究旨在探讨使用边缘贴合技术的非骨水泥髋臼杯进行翻修手术的中期结果。

方法

1996 年至 2014 年间,我们对 86 髋(74 例患者)进行了使用边缘贴合技术的非骨水泥髋臼杯翻修手术。我们评估了影像学结果,包括人工股骨头旋转中心的位置变化、假体松动情况以及初始间隙的填充情况。还评估了临床结果,包括 Harris 髋关节评分(HHS)和术后并发症。

结果

从 BHA 到术前手术的平均位置变化为 8.0 毫米向上和 4.1 毫米向内。从术前到术后的平均变化为 3.7 毫米向下和 2.4 毫米向外。所有病例均未发现假体松动;髋臼宿主骨与髋臼杯之间的初始间隙在 57 髋中的 53 髋(93%)中得到了填充。HHS 从术前的 65.9 平均提高到了末次随访的 83.8。术后脱位和假体周围骨折分别发生在 2 髋和 5 髋,均未再次翻修。

结论

使用边缘贴合技术的非骨水泥髋臼杯进行翻修全髋关节置换术治疗髋关节 OA 患者的 BHA 迁移,中期效果良好。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验