Clinic for Small Animal Surgery, Vetsuisse Faculty University of Zurich, Zurich, Switzerland.
Vet Surg. 2020 Dec;49(8):1517-1526. doi: 10.1111/vsu.13516. Epub 2020 Sep 30.
To evaluate spinal stabilization with tension band stabilization (TS) in cats compared to screw and polymethylmethacrylate fixation (SP).
Ex vivo study.
Sixteen feline thoracolumbar spinal specimens.
The intact specimens were mounted in a six-degree-of-freedom biaxial testing machine for nondestructive testing to obtain the neutral zones (NZ) and range of motion (ROM) in flexion and extension. Thereafter, nondestructive testing was consecutively performed after destabilization by disc fenestration and partial L1 corpectomy and after treatment with either TS or SP. Load to failure was compared after surgical treatment in flexion. Significance was assessed by Student's t test or Wilcoxon signed-rank test.
Range of motion was 26.4° ± 2.2° in TS constructs and 13.4° ± 2.1° in SP constructs (P = .0005). When flexion and extension were analyzed separately, no difference was found for ROM in flexion (SP, 7.0° ± 3.7°; TS, 8.3° ± 2.1°; P = .38). In extension, the mean displacement was 6.4° ± 2.7° and 18.1° ± 5.1° in SP and TS constructs, respectively (P = .0001). Neutral zone was 2.9° ± 0.6° and 7.5° ± 0.8° for the SP and TS groups, respectively (P = .0003). Screw and polymethylmethacrylate fixation constructs were two times stiffer (P = .045).
Tension band stabilization provided stability comparable to SP in flexion. In extension, ROM of SP constructs was half that of TS constructs. The mode of failure of TS was related to the limited dorsal bone stock of feline lumbar vertebrae.
Surgeons should be aware of the limited stability in extension provided by TS when it is used to stabilize thoracolumbar spinal injuries. Our results provide evidence to justify additional studies to clarify the type of fractures amenable to TS.
评估猫的张力带稳定(TS)与螺钉和聚甲基丙烯酸甲酯固定(SP)的脊柱稳定性。
体外研究。
16 个猫胸腰椎脊柱标本。
将完整标本安装在六自由度双轴试验机上进行无损检测,以获得屈伸时的中立区(NZ)和活动范围(ROM)。此后,在通过椎间盘开窗和部分 L1 椎体切除术进行去稳定化后,连续进行无损检测,然后分别用 TS 或 SP 进行治疗。在屈曲时比较手术治疗后的失效载荷。采用学生 t 检验或 Wilcoxon 符号秩检验评估显著性。
TS 组的活动范围为 26.4°±2.2°,SP 组为 13.4°±2.1°(P=0.0005)。当分别分析屈伸时,屈曲时的 ROM 无差异(SP,7.0°±3.7°;TS,8.3°±2.1°;P=0.38)。在伸展时,SP 和 TS 组的平均位移分别为 6.4°±2.7°和 18.1°±5.1°(P=0.0001)。SP 和 TS 组的 NZ 分别为 2.9°±0.6°和 7.5°±0.8°(P=0.0003)。SP 和 TS 组的固定结构刚性分别是两倍(P=0.045)。
TS 在屈曲时提供了与 SP 相当的稳定性。在伸展时,SP 组的 ROM 是 TS 组的一半。TS 的失效模式与猫腰椎的有限背侧骨量有关。
当用于稳定胸腰椎脊柱损伤时,外科医生应意识到 TS 在伸展时提供的稳定性有限。我们的结果提供了证据,证明有必要进行额外的研究来阐明 TS 适用的骨折类型。