Suppr超能文献

快速 TWIST 迭代重建提高手部动静脉畸形的诊断准确性。

Fast TWIST with iterative reconstruction improves diagnostic accuracy of AVM of the hand.

机构信息

Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany.

Interdisciplinary Center for Vascular Anomalies, University Clinic and Polyclinic of Radiology, University Hospital Halle, 06120, Halle (Saale), Germany.

出版信息

Sci Rep. 2020 Oct 1;10(1):16355. doi: 10.1038/s41598-020-73331-6.

Abstract

Very high temporal and spatial resolution is mandatory for the diagnosis of arteriovenous malformations (AVM) of the hand. Until now, magnetic resonance imaging (MRI) has not fulfilled both requirements simultaneously. This study presents how the combination of a very fast TWIST MRI (time-resolved angiography with interleaved stochastic trajectories) sequence and iterative reconstructions optimizes temporal as well as spatial resolution. 11 patients were examined at a 3-T MRI scanner with two different TWIST protocols: the standard and the study protocol, acquiring a data set every 5.57 s and 1.44 s respectively. The study data was retrospectively iteratively reconstructed with different regularization factors (0.001, 0.002, 0.004, 0.008). Results were compared using the sign-test. P-values < 0.05 were regarded statistically significant. With a low amount of contrast medium, the temporal resolution of the study protocol enabled the differentiation of arteries from veins in all patients whereas the signal-to-noise ratio (SNR) deteriorated. Depending on the regularization factors, SNR, delineation of arterial feeders and non-involved hand and interdigital arteries, as well as artefact levels varied. Overall, iterative reconstruction with regularization factor 0.004 achieved the best results, consequently showing the ability of MRI as a reliable diagnostic method in AVMs of the hand.

摘要

对于手部动静脉畸形 (AVM) 的诊断,需要非常高的时间和空间分辨率。到目前为止,磁共振成像 (MRI) 还不能同时满足这两个要求。本研究介绍了如何结合非常快速的 TWIST MRI(时间分辨血管造影与交错随机轨迹)序列和迭代重建来优化时间和空间分辨率。11 名患者在 3T MRI 扫描仪上接受了两种不同 TWIST 协议的检查:标准协议和研究协议,分别以 5.57 s 和 1.44 s 的时间间隔获取数据集。使用不同的正则化因子(0.001、0.002、0.004、0.008)对研究数据进行回顾性迭代重建。使用符号检验比较结果。P 值 < 0.05 被认为具有统计学意义。使用少量造影剂时,研究协议的时间分辨率使所有患者均能区分动脉和静脉,而信噪比 (SNR) 恶化。根据正则化因子,SNR、动脉供血动脉和未受累手部及指间动脉的描绘以及伪影水平有所不同。总的来说,使用正则化因子 0.004 进行迭代重建可获得最佳结果,从而表明 MRI 在手部 AVM 中作为可靠诊断方法的能力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7d7b/7529883/2f672374e413/41598_2020_73331_Fig1_HTML.jpg