Motion of the residual femur within the socket during gait is associated with patient-reported problems in transfemoral amputees.

作者信息

Gale Tom, Yang Shumeng, McGough Richard, Fiedler Goeran, Anderst William

机构信息

Department of Orthopaedic Surgery, University of Pittsburgh, USA.

Department of Orthopaedic Surgery, University of Pittsburgh, USA.

出版信息

J Biomech. 2020 Nov 9;112:110050. doi: 10.1016/j.jbiomech.2020.110050. Epub 2020 Sep 19.

Abstract

The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-reported comfort and function. The secondary goals were to assess within-subject step-to-step variability and between-subject variability in residual femur motion within the socket during gait. Dynamic biplane radiography, combined with conventional motion capture, was used to measure residual femur motion within the socket during treadmill walking for 10 unilateral transfemoral amputees. The questionnaire for persons with a transfemoral amputation (Q-TFA) was administered to assess prosthetic use, mobility, health problems, and global health. Increased femur pistoning (proximal-distal translation relative to the socket) correlated with worsening Q-TFA problem and global scores (ρ = 0.741, p = 0.04 and ρ = -0.783, p = 0.02, respectively). Average residual femur rotation ROMs were 7.3°±3.7°, 10.8°±4.4°, and 7.7°±4.8° for anterior tilt, internal-external rotation, and varus-valgus, respectively. Average residual femur translation ROMs were 8.6 mm ± 3.0 mm, 28.4 mm ± 13.9 mm, and 20.4 mm ± 7.2 mm for medial-lateral, pistoning, and anterior-posterior directions, respectively. Within-subject rotational and translational variability during gait averaged 2.8° and 2.0 mm or less, whereas the between-subject variability was up to 9.4° and 18.6 mm, which demonstrates residual femur motion relative to the socket is repeatable within subjects, but inconsistent across subjects during gait. The results suggest residual bone motion within the socket is a potential mechanism behind patient-reported problems and suggests a target for intervention aimed at improving transfemoral amputee quality of life.

摘要

本研究的目的是对步态期间残留在接受腔内的股骨运动进行定量描述,并探讨残留股骨运动与患者报告的舒适度和功能之间的关系。研究假设是,残留骨运动增加将与患者报告的较差舒适度和功能相关。次要目标是评估步态期间接受腔内残留股骨运动的受试者内步间变异性和受试者间变异性。动态双平面放射成像结合传统运动捕捉技术,用于测量10名单侧股骨截肢者在跑步机行走期间接受腔内的残留股骨运动。使用经股骨截肢者问卷(Q-TFA)评估假肢使用情况、活动能力、健康问题和整体健康状况。股骨活塞运动增加(相对于接受腔的近端-远端平移)与Q-TFA问题和整体评分恶化相关(分别为ρ = 0.741,p = 0.04和ρ = -0.783,p = 0.02)。前倾角、内-外旋转和内翻-外翻的平均残留股骨旋转ROM分别为7.3°±3.7°、10.8°±4.4°和7.7°±4.8°。内侧-外侧、活塞运动和前后方向的平均残留股骨平移ROM分别为8.6 mm±3.0 mm、28.4 mm±13.9 mm和20.4 mm±7.2 mm。步态期间受试者内的旋转和平移变异性平均分别为2.8°和2.0 mm或更小,而受试者间变异性高达9.4°和18.6 mm,这表明相对于接受腔的残留股骨运动在受试者内是可重复的,但在步态期间受试者之间不一致。结果表明,接受腔内的残留骨运动是患者报告问题背后的潜在机制,并提示了一个旨在改善股骨截肢者生活质量的干预目标。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验