Suppr超能文献

比较 Mini-FLOTAC 和离心粪便漂浮法检测猕猴桃(Apteryx mantelli)球虫(Eimeria spp.)。

Comparing the Mini-FLOTAC and centrifugal faecal flotation for the detection of coccidia (Eimeria spp.) in kiwi (Apteryx mantelli).

机构信息

School of Veterinary Science, Massey University, Private Bag 11 222, Palmerston North, New Zealand.

Wildbase, Massey University, Private Bag 11 222, Palmerston North, New Zealand.

出版信息

Parasitol Res. 2020 Dec;119(12):4287-4290. doi: 10.1007/s00436-020-06912-z. Epub 2020 Oct 12.

Abstract

Coccidia (Eimeria spp.) in brown kiwi (Apteryx mantelli) cause significant morbidity and mortality in captive rearing facilities. Monitoring the abundance of this parasite in individual birds is crucial for successful management of kiwi. This research compares the abilities of centrifugal faecal flotations (CFF) and a modified Mini-FLOTAC protocol to detect oocysts. We hypothesised that the Mini-FLOTAC would detect higher oocyst counts. Kiwi dropping samples (n = 10) were homogenized in MgSO (SG 1.28) and oocyst counts made with CFFs and Mini-FLOTAC counting chambers, with three replicates for each method. For CFF, 0.5 g of droppings were examined using standard methods. Mini-FLOTAC counts were made using a modified sample preparation compared with the manufacturer's protocol but still used a 1:20 dilution of droppings. Oocysts were quantified using light microscopy at ×100-300 magnification. A linear mixed-effects model by REML showed that oocyst per gram estimates via the Mini-FLOTAC method were 3.2 times higher (95% CI 2.4-4.5, p < 0.01) than the CFF results. This increased detection likely represents a more accurate estimation of parasite shedding and should be considered for use in research or applications requiring more accuracy, cost-effectiveness, or accessibility than the CFF provides.

摘要

棕色几维鸟(Apteryx mantelli)中的球虫(Eimeria spp.)在圈养繁殖设施中会导致严重的发病率和死亡率。监测这种寄生虫在个体鸟类中的丰度对于成功管理几维鸟至关重要。本研究比较了离心粪便浮选(CFF)和改良 Mini-FLOTAC 方案检测卵囊的能力。我们假设 Mini-FLOTAC 会检测到更高的卵囊计数。将几维鸟粪便样本(n=10)在 MgSO 4(SG 1.28)中均质化,并使用 CFF 和 Mini-FLOTAC 计数室进行卵囊计数,每种方法重复三次。对于 CFF,使用标准方法检查 0.5 克粪便。Mini-FLOTAC 计数使用与制造商协议相比有所修改的样品制备方法进行,但仍使用粪便 1:20 的稀释度。使用光学显微镜在 ×100-300 倍放大倍数下定量卵囊。通过 REML 的线性混合效应模型显示,通过 Mini-FLOTAC 方法估计的每克卵囊数是 CFF 结果的 3.2 倍(95% CI 2.4-4.5,p<0.01)。这种增加的检测可能代表着对寄生虫脱落的更准确估计,应该在需要比 CFF 更准确、更具成本效益或更易获得的研究或应用中考虑使用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验