Suppr超能文献

用于评估成人脊柱和下肢运动学的“帝国脊柱”标记集的可靠性及最小可检测变化

Reliability and minimal detectable change of the 'Imperial Spine' marker set for the evaluation of spinal and lower limb kinematics in adults.

作者信息

Deane J A, Papi E, Phillips A T M, McGregor A H

机构信息

Sackler MSK LAB, Sir Michael Uren Hub, Imperial College London, White City Campus, 86 Wood Lane, London, W12 0BZ, UK.

Structural Biomechanics, Department of Civil and Environmental Engineering, Imperial College London, London, UK.

出版信息

BMC Res Notes. 2020 Oct 22;13(1):495. doi: 10.1186/s13104-020-05295-9.

Abstract

OBJECTIVES

As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture.

RESULTS

The 'Imperial Spine' marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed. ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8-5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The 'Imperial Spine' marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.

摘要

目的

作为迈向全面评估腰痛患者运动的一步,本研究的目的是设计一套标记物(三段式刚性脊柱、骨盆和下肢模型),并使用三维运动捕捉技术评估该标记物集在健康成年人进行步态和从坐到站(STS)任务期间的可靠性和最小可检测变化(MDC)。

结果

使用“帝国脊柱”标记物集,采用可靠性研究的最小推荐样本量(n = 10),类内相关系数(ICC)最小值为0.70,最佳ICC为0.90,每个任务每个受试者重复9次试验,来评估步态和STS任务期间的相对峰值角度。检验了经验丰富和经验不足的使用者之间的测试者内和测试者间可靠性。计算了ICC、均值、标准误差(SEM)、布兰德-奥特曼95%一致性界限(LOA)和MDC。ICC值在两项任务中均显示出出色的测试者内和测试者间可靠性,尤其是在矢状面(大多数ICC>0.80)。SEM测量值在步态中(0.8 - 5.5°)低于STS任务(1° - 12.6°),MDC值也是如此。LOA显示出良好的一致性。“帝国脊柱”标记物集在健康成年人进行功能任务时使用是可靠的。未来需要在患者中进行评估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/69a9/7579883/3911a95f70c9/13104_2020_5295_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验