Suppr超能文献

植入式循环记录器可检测间歇性运动性能不佳的盛装舞步赛马的阵发性心房颤动。

Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance.

机构信息

Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Taastrup, Denmark.

Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

出版信息

Equine Vet J. 2021 Sep;53(5):955-963. doi: 10.1111/evj.13372. Epub 2020 Nov 23.

Abstract

BACKGROUND

Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF.

OBJECTIVES

The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance.

STUDY DESIGN

Prospective field study.

METHODS

Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6-28).

RESULTS

The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA.

MAIN LIMITATIONS

Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications.

CONCLUSIONS

This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long-term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses.

摘要

背景

关于马的阵发性心房颤动(PAF)的信息有限。事实上,未诊断的 PAF 可能导致表现不佳。由于间歇性发生,PAF 难以诊断。但是,通过皮下植入小型心电图设备(植入式环路记录器,ILR),可以连续自动检测 PAF。

目的

旨在研究 ILR 作为诊断表现不佳的马 PAF 的工具的潜力。

研究设计

前瞻性现场研究。

方法

十二匹间歇性表现降低的竞赛标准bred 快步马(平均年龄:六岁)被前瞻性纳入。ILR 被皮下植入第五或第六左肋间,并在研究期间收集 ILR 的数据,在此期间,这些马被跟踪中位持续时间为 7.5 个月(范围为 6-28 个月)。

结果

ILR 能够在十二匹赛马中检测到四匹的 PAF。ILR 在研究期间还检测到一匹马持续性心房颤动(AF)。ILRs 依赖于 RR 检测,96%的 R 波被正确识别。ILR 分类了 100 个 AF 发作,随后视觉心电图检查将 12 个分类为窦性节律(SR),28 个分类为窦性心律失常(SA),14 个分类为其他心律失常,46 个分类为 AF 发作。与 SR 和 SA 相比,AF 的连续差异均方根(RMSSD)值显着增加。

主要局限性

纳入的马匹数量较少,并且研究期间每匹马的持续时间不同。此外,在当前研究中无法评估设备的敏感性,并且 ILR 被证明具有高的假阳性错误分类率。

结论

本研究表明,ILR 可用于检测 PAF 发作,并且可以成为表现不佳的马的有用心电图工具。这种方法学为在马中评估 AF 发展和量化 AF 负担提供了一个平台。需要进一步包括健康和表现不佳的马的研究,以了解更多关于赛马中 PAF 的患病率。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/910b/8451893/8c048c8bad3a/EVJ-53-955-g003.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验