Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE, 19716, USA.
Ann Biomed Eng. 2021 Mar;49(3):1058-1068. doi: 10.1007/s10439-020-02649-z. Epub 2020 Oct 30.
One of the most common bath solutions used in musculoskeletal mechanical testing is phosphate buffered saline (PBS). In tendon, swelling induced by physiological PBS results in decreased tendon modulus and induces microstructural changes. It is critical to evaluate the multiscale mechanical behavior of tendon under swelling to interpret prior work and provide information to design future studies. We compared the effects of physiological PBS and 8% polyethylene glycol and saline bathing solutions on tendon multiscale tendon mechanics and damage as well as microstructure with TEM in order to understand the effect of swelling on tendon. At the tissue level, tendons in PBS had a lower modulus than SPEG samples. PBS samples also showed an increased amount of non-recoverable sliding, which is an analog for microscale damage. SPEG had a higher microscale to tissue-scale strain ratio, showing the fibrils experienced less strain attenuation. From the TEM data, we showed the fibril spacing of SPEG samples was more similar to fresh control than PBS. We concluded that swelling alters multiscale mechanics and damage in addition to tendon microstructure. Future mechanical testing should consider using SPEG as a bath solution with an osmotic pressure which preserves fresh tissue water content.
在肌肉骨骼机械测试中,最常用的浴液之一是磷酸盐缓冲盐水(PBS)。在肌腱中,生理 PBS 引起的肿胀会导致肌腱模量降低,并引起微观结构的变化。评估肿胀下肌腱的多尺度力学行为对于解释先前的工作并为未来的研究提供信息至关重要。我们比较了生理 PBS 和 8%聚乙二醇盐水浴液对肌腱多尺度力学和损伤以及 TEM 微观结构的影响,以了解肿胀对肌腱的影响。在组织水平上,PBS 中的肌腱的模量低于 SPEG 样品。PBS 样品还显示出不可恢复滑动量增加,这是微尺度损伤的模拟。SPEG 的微尺度到组织尺度应变比更高,表明原纤维经历的应变衰减较少。从 TEM 数据来看,我们发现 SPEG 样品的原纤维间距与新鲜对照更相似,而不是 PBS。我们得出的结论是,肿胀除了改变肌腱的微观结构外,还会改变多尺度力学和损伤。未来的力学测试应该考虑使用具有渗透压的 SPEG 作为浴液,以保持新鲜组织的含水量。