Suppr超能文献

锥形束计算机断层扫描测量根管牙本质厚度的准确性

Accuracy of Cone-Beam Computed Tomography in Measuring the Thickness of Radicular Dentin.

作者信息

Bunn Daiana Lopes, Corrêa Márcio, Dutra Kamile Leonardi, Schimdt Tamer Ferreira, Teixeira Cleonice da Silveira, Garcia Lucas da Fonseca Roberti, Bortoluzzi Eduardo Antunes

机构信息

Department of Dentistry, Endodontics Division, Health Sciences Center, UFSC - Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil.

出版信息

Braz Dent J. 2020 Sep-Oct;31(5):516-522. doi: 10.1590/0103-6440202002938.

Abstract

The purpose of this study was to evaluate the accuracy of Cone-Beam Computed Tomography (CBCT) in measuring radicular dentin thickness focused on intraradicular post placement planning treatment. Ten single-rooted human premolars were selected. The teeth were divided into three segments (cervical, middle and apical). The coronal face of the apical and middle sections was selected for the dentin thickness assessment; which was measured from the external root surface to the root canal wall, on the buccal, lingual, mesial, and distal surfaces of each tooth. In situ anatomical measurement was the reference standard, and the corresponding axial CBCT imaging were evaluated by the i-CAT software. The one-way ANOVA test and the Bonferroni post hoc test were applied to compare the groups (p>0.05). CBCT imaging measurements (p=0.003) overestimated the radicular dentin thickness compared to the reference standard. Descriptive analysis showed that the greatest difference between the reference standard and the tomographic measurement means were 0.20 mm. One-way ANOVA test found the statistical significant difference among group's measurements. Bonferroni correction demonstrated statistically significant difference only related lingual surface for the CBCT imaging measurements. CBCT imaging measurements overestimated the radicular dentin thickness. However, the measurement difference was clinically acceptable.

摘要

本研究的目的是评估锥形束计算机断层扫描(CBCT)在测量根管内牙本质厚度方面的准确性,重点是根管内桩植入的治疗计划。选取了10颗单根人前磨牙。将牙齿分为三个部分(颈部、中部和根尖部)。选择根尖部和中部的冠状面进行牙本质厚度评估;从每颗牙齿的颊侧、舌侧、近中侧和远中侧的牙根外表面到根管壁测量牙本质厚度。原位解剖测量作为参考标准,通过i-CAT软件对相应的轴向CBCT图像进行评估。应用单因素方差分析和Bonferroni事后检验比较各组(p>0.05)。与参考标准相比,CBCT图像测量(p=0.003)高估了根管内牙本质厚度。描述性分析表明,参考标准与断层测量平均值之间的最大差异为0.20mm。单因素方差分析发现各组测量之间存在统计学显著差异。Bonferroni校正显示,CBCT图像测量仅在舌侧表面存在统计学显著差异。CBCT图像测量高估了根管内牙本质厚度。然而,测量差异在临床上是可以接受的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验