Accuracy of an electrical impedance device in estimation of remaining dentin thickness vs cone beam computed tomography.

机构信息

Restorative Dentistry Department, Faculty of Dentistry, Delta University for Science and Technology, International Coastal Road, Gamsa, Mansoura, Egypt.

Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Algomhoria St, Mansoura, 35516, Egypt.

出版信息

Odontology. 2022 Jul;110(3):489-496. doi: 10.1007/s10266-021-00681-6. Epub 2022 Jan 11.

Abstract

The objective of this study is to compare the estimated values of remaining dentin thickness (RDT) recorded by a newly introduced electrical impedance device (Prepometer) with cone beam computed tomography (CBCT) and histological in situ measurement. A total number of thirty human molars were used in this study. A deep class I cavity was prepared. The RDT for each cavity was measured with Prepometer in three different points (mesial, middle, and distal). Same specimens were imaged with high-resolution Cone Beam Computed Tomography CBCT (0.1 mm voxel size) using I CAT next Generation Machine (Imaging Science International, Hatfield, PA, USA), to provide the highest possible accuracy of linear measurements. Finally, the specimens were vertically sectioned parallel to the long axis of the tooth in a mesiodistal direction splitting the cavity into two halves through its center. Then, the actual RDT of each half will be measured in the same three points using a digital caliper. The outcome of one-way ANOVA revealed that there was no significant difference in RDT values measured by prepometer device, CBCT, or histological sectioning methods (p > 0.05). Within the limitations of this laboratory study, prepometer seems to be a potential non-invasive accurate measuring tool for RDT. Based on the findings of this study, the Prepometer can be considered as an easily handled and less-expensive method compared to CBCT to evaluate the RDT. Also, it can be used in dental schools and with less-experienced operators to avoid traumatic exposures of the dental pulp.

摘要

本研究的目的是比较一种新引入的电导率设备(Prepometer)与锥形束计算机断层扫描(CBCT)和组织学原位测量记录的剩余牙本质厚度(RDT)的估计值。本研究共使用了 30 个人类磨牙。制备深 I 类洞。使用 Prepometer 在三个不同点(近中、中部和远中)测量每个洞的 RDT。使用成像科学国际公司(Imaging Science International)的 I CAT 下一代机(Imaging Science International,Hatfield,PA,USA)对相同的标本进行高分辨率锥形束计算机断层扫描(CBCT)(0.1mm 体素大小)成像,以提供线性测量的最高精度。最后,将标本沿牙长轴垂直于近远中方向切成两半,通过中心将腔分成两半。然后,使用数字卡尺在相同的三个点测量每个半的实际 RDT。单因素方差分析的结果表明,Prepometer 设备、CBCT 或组织切片测量方法测量的 RDT 值无显著差异(p>0.05)。在本实验室研究的限制内,Prepometer 似乎是一种潜在的非侵入性准确测量 RDT 的工具。基于这项研究的结果,与 CBCT 相比,Prepometer 可以被认为是一种更容易操作、更经济的方法,用于评估 RDT。此外,它可用于牙科学院和经验较少的操作人员,以避免对牙髓的创伤性暴露。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验