Abstract

The stability and longevity of the polyethylene-polypropylene glycol-stabilized insulin have been tested in vitro and in vivo in an implanted insulin-infusion device, the programmable implantable medication system (PIMS). In vitro tests demonstrated long-term compatibility with refill cycles of up to 3 mo, with a preparation of 400 U/ml. Total test period in vitro was 3.2 device-yr (combined time of device use). Insulin retained 88-93% native structure. A major modification, which was biologically active and nonimmunogenic, was identified and partially characterized. Examination of one device by scanning electron microscopy and X-ray microanalysis after 1 yr of insulin infusion revealed surfaces clean of insulin precipitate or other material along the entire insulin-delivery pathway. Surface analysis of the silicone-lined polyethylene catheters after 6 mo of infusion also showed no evidence of major insulin precipitate. In vivo stability trials were accomplished with PIMS implanted in diabetic dogs with an intraperitoneal delivery site. There has been no insulin blockage of the catheter of active pumps after 5.1 dog-yr (combined time of trials) of trials (up to 5 mo between refills in a single dog). Structural stability of insulin was analyzed by high-performance liquid chromatography. On average, 90.8% of the insulin sampled from the reservoir in vivo was native insulin, with an average of 96.2% retention of active forms.

摘要

在一种植入式胰岛素输注装置——可编程植入式给药系统(PIMS)中,对聚乙二醇 - 聚丙二醇稳定化胰岛素的稳定性和长效性进行了体外和体内测试。体外测试表明,对于400 U/ml的制剂,在长达3个月的再填充周期中具有长期兼容性。体外总测试期为3.2个装置年(装置使用的总时间)。胰岛素保留了88 - 93%的天然结构。鉴定出一种具有生物活性且无免疫原性的主要修饰,并对其进行了部分表征。在胰岛素输注1年后,通过扫描电子显微镜和X射线微分析对一个装置进行检查,结果显示在整个胰岛素输送路径上,表面没有胰岛素沉淀或其他物质。输注6个月后,对衬有硅胶的聚乙烯导管进行表面分析,也未发现明显的胰岛素沉淀迹象。在体内稳定性试验中,将PIMS植入患有糖尿病的犬类动物的腹膜内给药部位。在5.1个犬年(试验总时间)的试验后(单只犬每次再填充之间最长间隔5个月),活性泵的导管没有出现胰岛素堵塞情况。通过高效液相色谱法分析胰岛素的结构稳定性。平均而言,从体内储液器中采样的胰岛素中,90.8%是天然胰岛素,活性形式的平均保留率为96.2%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验