Suppr超能文献

聚焦超声诱导大鼠脑尾状核和丘脑血脑屏障通透性的局部差异。

A local difference in blood-brain barrier permeability in the caudate putamen and thalamus of a rat brain induced by focused ultrasound.

机构信息

Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Korea.

Center for Bionics, Korea Institute of Science and Technology, Seoul, Korea.

出版信息

Sci Rep. 2020 Nov 6;10(1):19286. doi: 10.1038/s41598-020-76259-z.

Abstract

A blood-brain barrier (BBB) opening induced by focused ultrasound (FUS) has been widely studied as an effective way of treating brain diseases. We investigate the effect of ultrasound's incidence angle at caudate putamen (Cp) and thalamus (Th) of the rat brain by inducing the same power of focused ultrasound that corresponds to the acoustic pressure of 0.65 MPa in free field. The BBB permeability (K) was quantitatively evaluated with dynamic contrast-enhanced magnetic resonance imaging. The group averaged (n = 11) maximum K at Cp (0.021 ± 0.012 min) was 1.39 times smaller than the K of Th (0.029 ± 0.01 min) with p = 0.00343. The group averaged (n = 6) ultrasound's incidence angles measured using the computed tomography image of rat skulls were compared with the maximum K and showed a negatively linear relation R = 0.7972). The maximum acoustic pressure computed from the acoustic simulation showed higher average acoustic pressures at Th (0.37 ± 0.02 MPa) compared to pressures at Cp (0.32 ± 0.01 MPa) with p = 0.138 × 10. More red blood cell were observed at the Th region compared to the Cp region in the tissue staining. These results indicate that localized characteristics of the sonication target within the subject should be considered for safer and more efficient BBB disruption induced by FUS.

摘要

血脑屏障(BBB)的开放是一种广泛研究的治疗脑部疾病的有效方法,通过聚焦超声(FUS)诱导。我们通过在自由场中产生相同功率的聚焦超声来研究大鼠脑尾状核(Cp)和丘脑(Th)处超声入射角对 BBB 的影响,该超声功率对应于 0.65 MPa 的声压。通过动态对比增强磁共振成像定量评估 BBB 的通透性(K)。Cp 组的平均(n=11)最大 K 值(0.021±0.012 min)比 Th 组的 K 值(0.029±0.01 min)小 1.39 倍,p=0.00343。用大鼠颅骨 CT 图像测量的组平均(n=6)超声入射角与最大 K 值进行比较,呈负线性关系 R=0.7972)。从声学模拟中计算出的最大声压显示 Th 处的平均声压(0.37±0.02 MPa)高于 Cp 处的平均声压(0.32±0.01 MPa),p=0.138×10。组织染色显示,与 Cp 区相比,Th 区的红细胞更多。这些结果表明,在 FUS 诱导的 BBB 破坏中,应考虑受试者中超声靶区的局部特征,以实现更安全、更有效的治疗。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ff8b/7648079/046b4e1711c1/41598_2020_76259_Fig1_HTML.jpg